A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Health care-associated bloodstream infections associated with negative- or positive-pressure or displacement mechanical valve needleless connectors. | LitMetric

Background: Health care-associated, central venous catheter-related bloodstream infections (HA-BSIs) are a major cause of morbidity and mortality. Needleless connectors (NCs) are an important component of the intravenous system. NCs initially were introduced to reduce health care worker needlestick injuries, yet some of these NCs may increase HA-BSI risk.

Methods: We compared HA-BSI rates on wards or intensive care units (ICUs) at 5 hospitals that had converted from split septum (SS) connectors or needles to mechanical valve needleless connectors (MV-NCs). The hospitals (16 ICUs, 1 entire hospital, and 1 oncology unit; 3 hospitals were located in the United States, and 2 were located in Australia) had conducted HA-BSI surveillance using Centers for Disease Control and Prevention definitions during use of both NCs. HA-BSI rates and prevention practices were compared during the pre-MV period, MV period, and post-MV period.

Results: The HA-BSI rate increased in all ICUs and wards when SS-NCs were replaced by MV-NCs. In the 16 ICUs, the HA-BSI rate increased significantly when SS-NCs or needles were replaced by MV-NCs (6.15 vs 9.49 BSIs per 1000 central venous catheter [CVC]-days; relative risk, 1.54; 95% confidence interval, 1.37-1.74; P < .001). The 14 ICUs that switched back to SS-NCs had significant reductions in their BSI rates (9.49 vs 5.77 BSIs per 1000 CVC-days; relative risk, 1.65; 95% confidence interval, 1.38-1.96; p < .001). BSI infection prevention strategies were similar in the pre-MV and MV periods.

Conclusions: We found strong evidence that MV-NCs were associated with increased HA-BSI rates, despite similar BSI surveillance, definitions, and prevention strategies. Hospital personnel should monitor their HA-BSI rates and, if they are elevated, examine the role of newer technologies, such as MV-NCs.

Download full-text PDF

Source
http://dx.doi.org/10.1086/648418DOI Listing

Publication Analysis

Top Keywords

ha-bsi rates
16
needleless connectors
12
health care-associated
8
bloodstream infections
8
mechanical valve
8
valve needleless
8
central venous
8
ha-bsi
8
ha-bsi rate
8
rate increased
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!