Unlabelled: The aim of this study was to compare the force relaxation between traditional latex elastics to different brands of non-latex elastics in a simulated saliva solution. The force relaxation of 6.35 mm (0.25 inch), 99 g (3.5 oz), non-colored latex elastics from Ormco Corp. and non-latex elastics from Phoenix Orthodontics, ClassOne Orthodontics, and Glenroe was tested. The elastics were stretched to 40 mm (1.57 inch) and the force produced by the elastics was then measured using a Mini 44 Instron machine.

Results: The latex elastics had an initial relaxation of 15 percent after 1 hour of incubation and maintained their reduced force after 24 hours of incubation. Non-latex elastics lost approximately 20 percent of their force after the first hour and continued to lose force after up to 24 hours of incubation resulting in as much as 48 percent force relaxation.

Conclusion: Latex elastics should be used whenever possible; however, when non-latex elastics are warranted, the clinician should take into account their greater initial forces, significant force relaxation, and variability among brands.

Download full-text PDF

Source

Publication Analysis

Top Keywords

force relaxation
16
latex elastics
16
non-latex elastics
16
elastics
11
force
9
elastics simulated
8
simulated saliva
8
saliva solution
8
force hours
8
hours incubation
8

Similar Publications

Retention mechanism in slalom chromatography: Perspectives on the characterization of large DNA and RNA biopolymers in cell and gene therapy.

J Chromatogr A

January 2025

Waters Corporation, Instrument/Core Research/Fundamental, Milford, MA, 01757, USA. Electronic address:

Significant progress has been made in the last two decades in producing small (<2μm), high-purity, and low-adsorption particles, columns and system hardware, for ultra-high pressure liquid chromatography (UHPLC). Simultaneously, the recent rapid expansion of cell and gene therapies for treating diseases necessitates novel analytical technologies for analyzing large (>2 kbp) plasmid double-stranded (ds) DNA (which encodes for the in vitro transcription (IVT) of single-stranded (ss) mRNA therapeutics) and dsRNAs (related to IVT production impurities) biopolymers. In this context, slalom chromatography (SC), a retention mode co-discovered in 1988, is being revitalized using the most advanced column technologies for improved determination of the critical quality attributes (CQAs) of such new therapeutics.

View Article and Find Full Text PDF

Understanding the ultrafast vibrational relaxation following photoexcitation of molecules in a condensed phase is essential to predict the outcome and improve the efficiency of photoinduced molecular processes. Here, the vibrational decoherence and energy relaxation of a binuclear complex, [Pt2(P2O5H2)4]4- (PtPOP), upon electronic excitation in liquid water and acetonitrile are investigated through direct adiabatic dynamics simulations. A quantum mechanics/molecular mechanics (QM/MM) scheme is used where the excited state of the complex is modeled with orbital-optimized density functional calculations while solvent molecules are described using potential energy functions.

View Article and Find Full Text PDF

Background: The therapeutic armamentarium for heart failure with preserved ejection fraction (HFpEF) remains notably constrained. A factor contributing to this problem could be the scarcity of in vitro models for HFpEF, which hinders progress in developing new therapeutic strategies. Here, we aimed at developing a novel, comorbidity-inspired, human, in vitro model for HFpEF.

View Article and Find Full Text PDF

Efflux pumps that transport antibacterial drugs out of bacterial cells have broad specificity, commonly leading to broad spectrum resistance and limiting treatment strategies for infections. It remains unclear how efflux pumps can maintain this broad spectrum specificity to diverse drug molecules while limiting the efflux of other cytoplasmic content. We have investigated the origins of this broad specificity using theoretical models informed by the experimentally determined structural and kinetic properties of efflux pumps.

View Article and Find Full Text PDF

Objective: Knee-adjacent subcutaneous fat (kaSCF) has emerged as a potential biomarker and risk factor for osteoarthritis (OA) progression. This study aims to develop an AI-based tool for the automatic segmentation of kaSCF thickness and evaluate the cross-sectional associations between kaSCF, cartilage thickness, MRI-based cartilage T relaxation time, knee pain, and muscle strength independent of BMI.

Design: Baseline 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!