Aims: Transoesophageal echocardiography (TEE) with contrast administration is still considered as the reference method for the detection of patent foramen ovale (PFO) with interatrial shunt, but it is a semi-invasive exam. The aim of the present study is to evaluate a role of two- and three-dimensional transthoracic echocardiography (TTE and R3DTE) as a diagnostic alternative to transcranial Doppler ultrasound (TCD) and TEE for detection of atrial right-to-left shunt.

Methods And Results: Seventy-five patients with history of cerebrovascular events were subjected to four diagnostic examinations: TCD, TTE, R3DTE, and TEE, with bubble contrast. Bubbles in the left atrium within three cardiac cycles were considered diagnostic for PFO and later as a pulmonary shunt. Greater than 20 bubbles in the left atrium were considered a large shunt and <20 a small shunt. Every exam was read blinded to the results of the others. From the 75 enrolled patients, 62 (82.6%) patients showed right-to-left shunt with TEE; the results were also positive in 53 patients using TCD (70.6%), in 53 using R3DTE (70.6%), and in 55 using TTE (73.3%) (P = NS). There is a statistically significant superiority for TEE in the capacity of detecting shunts compared with TCD (P < 0.024), TTE (P < 0.018), and R3DTE (P < 0.018). The TEE presents a superior ability to recognize mild/moderate interatrial shunts respect to other exams (P = 0.003), without differences for shunts of high degree. In comparison to the TEE, the sensitivity is 89% for TTE, 88% for R3DTE, and 85% for TCD; the specificity is 100% for TTE and R3DTE, and 90% for TCD; the positive predictive value is 100% for TTE and R3DTE, and 98% for TCD; and the negative predictive value is 65% for TTE, 65% for R3DTE, and 53% for TCD. Considering only for mild/moderate shunts, the diagnostic accuracy is clearly inferior (sensitivity 63% for TTE, 58% for R3DTE, and 53% for TCD).

Conclusion: In this cohort of patients, TEE confirms the role of 'gold standard' exam for the detection of PFO; the non-invasive methods, and the TTE in particular, present a good diagnostic accuracy, but are inferior to the TEE because of the low negative predictive value and the non-optimal detection of small shunts. If the only purpose of TEE is the detection of significative interatrial shunt, TEE can be replaced by TTE. The R3DTE presents a good diagnostic accuracy, provides a better anatomical definition of the interatrial septum, and may have a role in this setting of patients, but does not add a lot to the TTE for the diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejechocard/jep165DOI Listing

Publication Analysis

Top Keywords

two- three-dimensional
8
detection patent
8
patent foramen
8
foramen ovale
8
tte r3dte
8
bubbles left
8
left atrium
8
transthoracic second
4
second harmonic
4
harmonic two-
4

Similar Publications

Background: The purpose of this study was to compare outcomes and adverse events between three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) in patients undergoing long-course neoadjuvant radiation therapy (NA-RT) for locally advanced rectal adenocarcinoma (LARC).

Methods: We retrospectively analyzed a total of 47 consecutive patients who received NA-RT for LARC between January 2011 and September 2022. Seven and 40 patients were diagnosed with clinical stages II and III, respectively.

View Article and Find Full Text PDF

Gibbons, a type of lesser ape, are brachiators but also walk bipedally and without forelimb assistance, not only on the ground but also on tree branches. The arboreal bipedal walking strategy of the gibbons has been studied in previous studies in relation to two-dimensional (2D) kinematic analysis. However, because tree branches and the ground differ greatly in width, leading to a constrained foot contact point on the tree branches, gibbons must adjust their 3D joint motions of trunk and hindlimb on the tree branches.

View Article and Find Full Text PDF

Serendipitous high-resolution structure of Escherichia coli carbonic anhydrase 2.

Acta Crystallogr F Struct Biol Commun

February 2025

Department of Biological Chemistry, University of Michigan, Ann Arbor, MI 48109, USA.

X-ray crystallography remains the dominant method of determining the three-dimensional structure of proteins. Nevertheless, this resource-intensive process may be hindered by the unintended crystallization of contaminant proteins from the expression source. Here, the serendipitous discovery of two novel crystal forms and one new, high-resolution structure of carbonic anhydrase 2 (CA2) from Escherichia coli that arose during a crystallization campaign for an unrelated target is reported.

View Article and Find Full Text PDF

The design and implementation of successful rotational flaps of the scalp remains a complex process. There are several described techniques, all of which are based on a two-dimension surface, absent consideration of the convexity, and thereby three-dimensional nature of the scalp. This has contributed to flaps that are either too small or unnecessarily large in a bid to compensate.

View Article and Find Full Text PDF

We examined the intricate mechanisms underlying visual processing of complex motion stimuli by measuring the detection sensitivity to contraction and expansion patterns and the discrimination sensitivity to the location of the center of motion (CoM) in various real and unreal optic flow stimuli. We conducted two experiments (N = 20 each) and compared responses to both "real" optic flow stimuli containing information about self-movement in a three-dimensional scene and "unreal" optic flow stimuli lacking such information. We found that detection sensitivity to contraction surpassed that to expansion patterns for unreal optic flow stimuli, whereas this trend was reversed for real optic flow stimuli.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!