The Ca(1-x)Mg(x)Al12O19:Mn4+ compounds were prepared by liquid phase precursor (LPP) methods for use in white light emitting diodes (LEDs) based on nano red phosphor. The effect of adding Mg element on the relative emission characteristics of Ca(1-x)Mg(x)Al12O19:Mn4+ is discussed in terms of the charge compensation effect. The LPP synthesis, the relative emission intensity of Ca(1-x)Mg(x)Al12O19:Mn4+ containing ratio of 0.05 MgO was approximately 70% higher than that of the LPP synthesized Ca(1-x)Mg(x)Al12O19:Mn4+ red phosphor. These results indicate that the use of an appropriate LPP synthesis improve excellence the luminescent efficiency, particularly for the samples prepared with the optimized firing temperature of 1450 degrees C for 1 hour.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jnn.2009.1753DOI Listing

Publication Analysis

Top Keywords

liquid phase
8
phase precursor
8
red phosphor
8
relative emission
8
lpp synthesis
8
nano particle
4
particle phosphor
4
phosphor formation
4
formation luminescent
4
luminescent characteristic
4

Similar Publications

Long-acting injectable in situ forming implants: Impact of polymer attributes and API.

Int J Pharm

December 2024

Department of Pharmaceutical Sciences, University of Connecticut, Storrs, CT 06269, USA. Electronic address:

Poly(DL-lactide-co-glycolide) (PLGA) and N-methyl-2-pyrrolidone (NMP)-based in situ forming implants are liquid formulations that solidify through phase separation following injection into the body. Drug is dissolved or suspended in the final formulation liquid prior to injection. Depending on the polymers used, the depots formed can deliver drug over different periods of time.

View Article and Find Full Text PDF

A highly sensitive and rapid LC-MS/MS method was developed and validated for the quantification of dexamethasone in rat plasma and brain tissue. Protein precipitation method was used for sample preparation. The separation of dexamethasone and the IS (labetalol) was achieved on an Atlantis dC column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 25/75, v/v) delivered at 0.

View Article and Find Full Text PDF

Simultaneous Determination of Vitamins A and E and Their Generated Metabolites in Human Serum by LC-MS/MS.

Biomed Chromatogr

January 2025

Beijing Harmony Health Medical Diagnostics Co., Ltd., Beijing, China.

In the context of personalized and precision medicine, simultaneous monitoring of different forms of vitamins A and E and their metabolites could help us better understand the status of vitamins A and E in the body. The aim of this study was to establish a method for simultaneous determination of 13 kinds of vitamins A and E and their metabolites in human serum. Serum samples were directly detected by LC-MS/MS after deproteinization.

View Article and Find Full Text PDF

Plant metabolites known as cucurbitacins are known to impart an unpleasant bitter taste to edible fruits and even lead to severe health complications after the ingestion of relatively high amounts. In this study, an analytical method based on reversed phase liquid chromatography with combined detection by UV spectroscopy and atmospheric pressure chemical ionization high-resolution single/tandem mass spectrometry was applied to confirm the occurrence of four cucurbitacins (B, D, and R, and 23,24-dihydro cucurbitacin B) previously inferred in unexpectedly bitter-tasting fruits of an Italian variety (Scopatizzo) of unripe melon (Cucumis melo L.), known for the sweetness of its fruits.

View Article and Find Full Text PDF

Study on the mechanism of erosion and wear of elbow pipes by coarse particles in filling slurry.

Sci Rep

December 2024

The Ministry of Education Key Laboratory of High Efficiency Mining and Safety for Metal Mines & School of Civil and Resources Engineering, University of Science and Technology Beijing, Beijing, 100083, People's Republic of China.

Coarse particles in filling slurry are the primary factor causing wear in filling elbow pipes, and the wear mechanism of these particles on the pipes is influenced by various factors. To study the erosion and wear mechanism of elbow pipes caused by coarse particles, the motion state of coarse particles under different curvature radii, coarse particle gradations, and pipe diameters was investigated using a simulation method based on the coupling of Fluent and EDEM software, grounded in theories of fluid mechanics, rheology, and solid-liquid two-phase flow. The study explored the impact patterns and locations of wear induced by coarse particles on filling elbow pipes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!