A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of bone impingement prediction in pre-operative planning for shoulder arthroplasty. | LitMetric

In shoulder arthroplasty, malpositioning of prostheses often leads to reduced postoperative range of motion (ROM) and complications such as impingement, loosening, and dislocation. Furthermore, the risk of impingement complications increases when reverse total prostheses are used. For this purpose a pre-operative planning system was developed that enables surgeons to perform a virtual shoulder replacement procedure. The present authors' pre-operative planning system simulates patient-specific bone-determined ROM meant to reduce the risk of impingement complications and to improve the ROM of patients undergoing shoulder replacement surgery. This paper describes a validation experiment with the purpose of ratifying the clinical applicability and usefulness of the ROM simulation module for shoulder replacement surgery. The experiment was performed on cadaveric shoulders. A data connection was set up between the software environment and an existing intra-operative guidance system to track the relative positions of the bones. This allowed the patient-specific surface models to be visualized within the software for the position and alignment of the tracked bones. For both shoulders, ROM measurements were recorded and tagged with relevant information such as the type of prosthesis and the type of movement that was performed. The observed ROM and occurrences of impingement were compared with the simulated equivalents. The median deviation between observed impingement angles and simulated impingement angles was -0.30 degrees with an interquartile range of 5.20 degrees (from -3.40 degrees to 1.80 degrees). It was concluded that the ROM simulator is sufficiently accurate to fulfil its role as a supportive instrument for orthopaedic surgeons during shoulder replacement surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1243/09544119JEIM531DOI Listing

Publication Analysis

Top Keywords

shoulder replacement
16
pre-operative planning
12
replacement surgery
12
shoulder arthroplasty
8
risk impingement
8
impingement complications
8
planning system
8
impingement angles
8
impingement
7
rom
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!