A reference method to accurately define kinetics in response to the ingestion of glucose in terms of total, exogenous and endogenous glucose is to use stable-isotope-labelled compounds such as 2H and 13C glucose followed by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) analysis. The use of the usual pentaacetyl (5Ac) derivative generates difficulties in obtaining accurate and reproducible results due to the two chromatographic peaks for the syn and anti isomers, and to the isotopic effect occurring during acetylation. Therefore, the pentaacetylaldononitrile derivative (Aldo) was validated for both isotopes, and compared with the 5Ac derivative. A correction factor including carbon atom dilution (stoichiometric equation) and the kinetic isotopic effect (KIE) was determined. Analytical validation results for the 2H GC/MS and 13C GC/C/IRMS measurements produced acceptable results with both derivatives. When 2H enrichments of plasma samples were < or = 1 mol % excess (MPE), the repeatability (RSD(Aldo Intra assay and Intra day) <0.94%, RSD(5Ac Intra assay and Intra day) <3.29%), accuracy (Aldo <3.4%, 5Ac <29.0%), and stability of the derivatized samples were significantly better when the Aldo derivatives of the plasma samples were used (p < 0.05). When the glucose kinetics were assessed in nine human subjects, after glucose ingestion, the plasma glucose 2H enrichments were identical with both derivatives, whereas the 13C enrichments needed a correction factor to fit together. Due to KIE variation, this correction factor was not constant and had to be calculated for each batch of analyses, to obtain satisfactory results. Mean quantities of exogenous glucose exhibit marked difference (20.9 +/- 1.3g (5Ac) vs. 26.7 +/- 2.5g (Aldo)) when calculated with stoichiometric correction, but fit perfectly when calculated after application of the correction factor (22.1 +/- 1.3g (5Ac) vs. 22.9 +/- 1.9g (Aldo)). Finally, the pentaacetylaldononitrile derivative, used here in GC/C/IRMS for the first time, enables measurement of 2H and 13C enrichments in plasma glucose with a single sample preparation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.4294DOI Listing

Publication Analysis

Top Keywords

pentaacetylaldononitrile derivative
8
gas chromatography/mass
8
chromatography/mass spectrometry
8
gas chromatography/combustion/isotope
8
chromatography/combustion/isotope ratio
8
ratio mass
8
mass spectrometry
8
5ac derivative
8
validation pentaacetylaldononitrile
4
derivative
4

Similar Publications

A reference method to accurately define kinetics in response to the ingestion of glucose in terms of total, exogenous and endogenous glucose is to use stable-isotope-labelled compounds such as 2H and 13C glucose followed by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) analysis. The use of the usual pentaacetyl (5Ac) derivative generates difficulties in obtaining accurate and reproducible results due to the two chromatographic peaks for the syn and anti isomers, and to the isotopic effect occurring during acetylation. Therefore, the pentaacetylaldononitrile derivative (Aldo) was validated for both isotopes, and compared with the 5Ac derivative.

View Article and Find Full Text PDF

Determination of [(13)C]galactose enrichment in human plasma by gas chromatography/positive chemical ionization tandem mass spectrometry.

J Mass Spectrom

February 2000

Center for Cancer Pharmacology, Department of Pharmacology, University of Pennsylvania, 421 Curie Boulevard, Philadelphia, Pennsylvania, 19104-6160, USA.

Galactosemia is a potentially fatal disease resulting from a deficiency of galactose-1-phosphate uridyl transferase. In order to perform mechanistic studies designed to elucidate further the etiology of the disease, we required a method to monitor (13)C enrichment in plasma galactose following a single oral dose or intravenous infusion of [1-(13)C]galactose. Determinations of plasma [(13)C]galactose enrichment requires methodology with extremely high specificity because of potential interference from other low molecular mass plasma constituents and from glucose, an isomer which is present in much higher concentrations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!