Background: The heterogeneous structure of carotid atherosclerotic plaques may be better understood if it is related to blood flow variations, influencing gene expression and cellular functions. Upstream of the maximum stenosis there is laminar blood flow and high shear stress, downstream there is turbulence and low shear stress. We studied if these variations were associated with differences in plaque morphology and composition between sites located up- and downstream of the maximum stenosis in symptomatic carotid plaques.
Methods: Patients with symptomatic carotid stenosis were examined with magnetic resonance angiography to localize the maximum stenosis in-vivo, prior to endarterectomy. In 41 endarterectomized specimens, transverse tissue sections prepared up- and downstream of the maximum stenosis were compared using histopathology and immunohistochemistry.
Results: The location of maximum stenosis relative the carotid bifurcation varied considerably between plaques. Compared with the downstream side, the upstream side of the stenosis had higher incidence of severe lesions with cap rupture and intraplaque hemorrhage, more macrophages, less smooth muscle cells and more collagen.
Conclusions: The up- and downstream sides of symptomatic carotid plaques differed in plaque morphology and composition. This implies that the intraplaque location of sampling sites may be a confounding factor in studies of atherosclerotic plaques.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000255965 | DOI Listing |
Background: In developing countries, rheumatic mitral valve stenosis (MS) is still a problem and its progression leads to left atrial (LA) damage. Due to the complexity of the LA geometry, currently used techniques like antero-posterior dimension (LAD) and 2D echo derived LA volume (LAV) have several limitations that are corrected by 3D derived LA volumes in addition to functional evaluation.
Purpose: To assess the LA functions using 2D speckle tracking echocardiography and 3D transthoracic echocardiography in patients with clinically significant MS in comparison to normal healthy subjects.
Quant Imaging Med Surg
January 2025
Department of Echocardiography, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background: Carotid ultrasound is a helpful approach for classifying cardiovascular risk. Quantitative flow ratio (QFR) is used to evaluate functionally significant coronary artery stenosis (CAS). The aim of this prospective study was to investigate the correlation between carotid artery features from carotid ultrasound and functionally significant CAS.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan.
Background: The long-term valve durability of supra-annular self-expanding valves (SEV) and intra-annular balloon-expandable valves (BEV) in patients with small aortic annuli remains unexplored.
Aims: This study aimed to determine the long-term bioprosthetic valve durability with SEV versus BEV in patients with small aortic annuli.
Methods: This retrospective study included patients with severe aortic stenosis (AS) and an aortic annulus area of 430 mm or less who underwent transcatheter aortic valve replacement using SEV and BEV between October 2009 and December 2022.
Pediatr Cardiol
January 2025
School of Medicine, Children's Hospital Colorado, The Heart Institute, University of Colorado Denver|Anschutz Medical Campus, 13123 E 16Th Ave, Box 100, Aurora, CO, 80045-2560, USA.
Though major complications during transcutaneous pulmonary valve replacement (TPVR) are rare, clinically-significant ventricular arrythmia (CSVA) has been reported following self-expanding valve placement. We assess whether alterations in valve frame dimensions and geometry within the right ventricular outflow tract (RVOT) post-implantation in patients who underwent TPVR with Harmony TPV25 or Alterra contribute to CSVA risk. A single center review was performed of patients who underwent TPVR with either Harmony TPV25 or Alterra Pre-stent between August 2019 and April 2023.
View Article and Find Full Text PDFCureus
December 2024
Department of Cardiology, Geetanjali Medical College and Hospital, Udaipur, IND.
Background Carotid artery stenting is a well-established alternative treatment to carotid endarterectomy for carotid artery stenosis for preventing stroke. This study assessed the procedural and clinical outcomes in patients undergoing carotid artery stenting in a tertiary care center in India. Methods A total of 39 patients underwent carotid artery stenting from January 2022 to December 2023, with different embolic protection devices and carotid stents.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!