Background And Purpose: MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 x 0.9 x 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities.

Materials And Methods: A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic).

Results: Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95% CI, 0.97-1.0]; sensitivity, 97% [84%-100%]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76% [64%-84%]; AUC, 0.92 [0.88-0.96]), followed by TOF MRV (72% [59%-81%]; AUC, 0.93 [0.88-0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67% (30%-90%). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66% [46%-81%]; AUC, 0.88 [0.78-0.97]). Specificities of all modalities ranged from 96% to 99%.

Conclusions: Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7963956PMC
http://dx.doi.org/10.3174/ajnr.A1869DOI Listing

Publication Analysis

Top Keywords

combo-4d mrv
16
diagnostic accuracy
12
cortical veins
12
accuracy combined
8
combined dynamic
8
mrv
8
imaging modalities
8
tof mrv
8
dural sinuses
8
thrombosed cortical
8

Similar Publications

Background And Purpose: MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!