This paper presents a model for determining the path of the instantaneous helical axis (IHA) that optimally represents human planar motions with one functional degree of freedom (fDOF). A human movement is said to have one fDOF when all degrees of freedom (DOFs) are coordinated such that all the kinematic variables can be expressed, across movement repetitions, as functions of only one independent DOF, except for a small natural intercycle variability quantified as lower than a prespecified value. The concept of fDOF allows taking into account that, due to motor coordination, human movements are executed in a repeatable manner. Our method uses the measurement of several repetitions of a given movement to obtain the optimal average IHA path. The starting point is a change of variables, from time to a joint position magnitude (generally an angle). In this way, instead of operating with the time-dependent single-valued trajectory of the successive cycles, our model permits the representation of any motion variable (e.g. positions and their time derivatives) as a cloud of points dependent on the joint angle. This allows the averaging to be performed over the displacements and their derivatives before determining the mean IHA path. We thus avoid the nonlinear magnification of errors and variability inherent in the IHA computation. Moreover, the IHA path can be considered as a geometric attribute of the joint and the type of motion, rather than of each single movement execution. An experiment was performed that show the accuracy and usefulness of the method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2009.09.023 | DOI Listing |
Ann Biomed Eng
October 2023
Orthopaedic Bioengineering Research Center, Newton-Wellesley Hospital/Massachusetts General Brigham, Newton, MA, 02462, USA.
This study aimed to develop and validate a novel flexion axis concept by calculating the points on femoral condyles that could maintain constant heights during knee flexion. Twenty-two knees of 22 healthy subjects were investigated when performing a weightbearing single leg lunge. The knee positions were captured using a validated dual fluoroscopic image system.
View Article and Find Full Text PDFArch Orthop Trauma Surg
October 2022
Orthopaedic Bioengineering Research Center, Newton-Wellesley Hospital, 159 Wells Ave, Newton, MA, 02459, USA.
Background: Gap balance of the knee at 0° and 90° of flexion has been pursued in total knee arthroplasty (TKA) with the trans-epicondyle axis (TEA) as a reference. This study investigated the height changes of the tibiofemoral articulation and compared the data with the femoral condyle height changes measured using different flexion axes.
Materials And Methods: Twenty healthy knees were investigated during an in vivo weightbearing flexion using a technique combining MRI and a dual fluoroscopic imaging system (DFIS).
Knee Surg Sports Traumatol Arthrosc
February 2021
Orthopaedic Bioengineering Research Center, Newton-Wellesley Hospital, 159 Wells Ave, Newton Centre, Newton, MA, 02459, USA.
Purpose: It is a challenge to evaluate the maintenance of medial and lateral soft tissue balance in total knee arthroplasty (TKA). This study aimed to determine the "isoheight" points and the "isoheight" axis (IHA) that can measure constant medial/lateral condyle heights during flexion of the knee, and compare the IHA with two major anatomical axes, the transepicondylar axis (TEA) and the geometric center axis (GCA).
Methods: Twenty-two healthy human knees were imaged using a combined MRI and dual fluoroscopic imaging system while performing a single-legged lunge (0°-120°).
J Biomech
February 2020
Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany; DUO - Duderstadt Trauma Surgery and Orthopaedics, Westertorstr. 7, 37115 Duderstadt, Germany. Electronic address:
Total disc arthroplasty (TDA) increases the risk of adjacent segment disease (ASD). Kinematic analyses are necessary to compare the intact condition (IC) with alterations after TDA to develop better prostheses. A well-established 6D measuring apparatus (resolution < 2.
View Article and Find Full Text PDFEur Spine J
September 2017
Biomechanical Working Group, University of Göttingen, Göttingen, Germany.
Purpose: The kinematical properties of C5/C6 segments in axial rotation are evaluated before and after total disc arthroplasty (TDA) with PRESTIGE-and BRYAN Cervical Disc (Medtronic) under flexion/extension as parameters and compared with those of C3/C4.
Methods: Eight human segments were stimulated by triangularly varying, axially directed torque (T (t)) under compressing static axial preloads. Using a 6D-measuring device with high resolution, the response of segmental motion was characterized by the instantaneous helical axis (IHA).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!