Analysis of surface roughness and surface free energy characteristics of various orthodontic materials.

Am J Orthod Dentofacial Orthop

Department of Orthodontics, School of Dentistry, Seoul National University, Seoul, Korea.

Published: November 2009

Introduction: The purpose of this study was to analyze the differences in surface characteristics of various orthodontic materials; this might provide valuable information on bacterial adhesion to orthodontic materials.

Methods: Surface roughness (SR) and surface free energy (SFE) characteristics of 5 orthodontic adhesives (2 composites resins, 2 resin-modified glass ionomer cements, and 1 compomer), 5 bracket materials (2 stainless steel, 1 monocrystalline sapphire, 1 polycrystalline alumina, and 1 plastic) and bovine incisors were investigated by using confocal laser scanning microscopy and the sessile drop method.

Results: There were significant differences in SR and SFE characteristics among orthodontic materials. Bovine incisors showed the roughest surface, and monocrystalline sapphire showed the smoothest surface. However, there were only small variations in SR (less than 0.3 mum) among the materials, except for bovine incisors. In contrast to SR, there were big differences in SFE characteristics among materials. Generally, bracket materials showed lower SFE--specifically, dispersive and polar components on their surfaces--than orthodontic adhesives. Resin-modified glass ionomer cements had the highest SFE, dispersive component, and polarity; these conditions are more favorable for bacterial adhesion.

Conclusions: This study suggests that SFE characteristics can influence bacterial adhesion to orthodontic materials more than SR, and bracket materials might have less favorable SFE characteristics for bacterial adhesion than orthodontic adhesives.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2007.11.032DOI Listing

Publication Analysis

Top Keywords

sfe characteristics
20
characteristics orthodontic
16
orthodontic materials
16
bacterial adhesion
12
adhesion orthodontic
12
orthodontic adhesives
12
bracket materials
12
bovine incisors
12
materials
9
surface roughness
8

Similar Publications

People with low back pain (LBP) display an altered movement pattern during functional activities. Exercise-based treatments improve the altered pattern, but there is individual variability in the response to treatment. This study investigates the moderating effect of person-specific characteristics on a movement pattern at baseline and change over time in the pattern in people with chronic LBP who received motor skill training (MST) or strength and flexibility exercise (SFE).

View Article and Find Full Text PDF

Purpose: This study aims to compare the surface roughness (SR), contact angle (CA), surface free energy (SFE), and bacterial adhesion of resin-based materials used in additive, subtractive, and conventional manufacturing techniques.

Materials And Methods: This study involved four groups of 23 specimens: Indirect conventional resin composite (ICRC), subtractively manufactured resin composite (SMRC), additively manufactured resin composite (AMRC), and soda-lime-silica glass (SLSG). One specimen per group was analyzed by Energy Dispersive X-ray Spectroscopy (EDS) before polishing.

View Article and Find Full Text PDF

Preparation, Characterization and In Vitro Anticancer Activity of Sulforaphene-Loaded Solid Lipid Nanoparticles.

Foods

December 2024

Key Laboratory for Deep Processing of Major Grain and Oil, Ministry of Education, Wuhan Polytechnic University, Wuhan 430023, China.

Sulforaphane (SFE) extracted from radish seeds has garnered significant research attention in recent years due to its notable biological activities, particularly its anticancer properties. However, SFE is highly sensitive to the environment; therefore, solid lipid nanoparticles (SLNs) were used to embed SFE to enhance its stability. SFE-SLNs were characterized and compared with free SFE to assess the impact of SLNs on SFE.

View Article and Find Full Text PDF

Optimal biomechanical choice of implant placement in various pilon fracture types: a finite element study.

BMC Musculoskelet Disord

November 2024

Department of Orthopedics, General Hospital of Central Theater Command of PLA, (Wuhan General Hospital of Guangzhou Command, Previously), Hubei Province, NO. 627, Wuluo Road, Wuhan, 430030, P.R. China.

Article Synopsis
  • The study examines the impact of fracture displacement directions on stress distribution in both bones and implants for pilon fractures, a type of ankle injury.
  • Different fracture types were categorized and assessed under specific loading conditions, utilizing various plate placements and lag screws for treatment.
  • Results indicated significant differences in stress levels among the different fracture subtypes, leading to recommendations for optimal implant placement based on fracture type to improve surgical outcomes.
View Article and Find Full Text PDF
Article Synopsis
  • - Hydroxyapatite (HAP) is widely used in medical fields for bone repair and implants, and recent studies are focusing on making orthopedic implants more biocompatible with HAP.
  • - The research combines HAP with a lipid matrix to enhance the characteristics of poly(lactic acid) (PLA) implants, utilizing the Langmuir-Blodgett method for effective deposition on PLA surfaces.
  • - Results show that a 5:1 mixture of dihexadecyl phosphate (DHP) and HAP improves the surface properties of PLA, potentially leading to better integration into bone and fewer bacteria adhering to the implants.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!