A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hypoxic pulmonary vasodilation: a paradigm shift with a hydrogen sulfide mechanism. | LitMetric

Hypoxic pulmonary vasoconstriction (HVC), an intrinsic and assumed ubiquitous response of mammalian pulmonary blood vessels, matches regional ventilation to perfusion via an unknown O(2)-sensing mechanism. Global pulmonary hypoxia experienced by individuals suffering from chronic obstructive pulmonary disease or numerous hypoventilation syndromes, including sleep apnea, often produces maladaptive pulmonary hypertension, but pulmonary hypertension is not observed in diving mammals, where profound hypoxia is routine. Here we examined the response of cow and sea lion pulmonary arteries (PA) to hypoxia and observed the expected HVC in the former and a unique hypoxic vasodilation in resistance vessels in the latter. We then used this disparate response to examine the O(2)-sensing mechanism. In both animals, exogenous H(2)S mimicked the vasoactive effects of hypoxia in isolated PA. H(2)S-synthesizing enzymes, cystathionine beta-synthase, cystathionine gamma-lyase, and 3-mercaptopyruvate sulfur transferase, were identified in lung tissue from both animals by one-dimensional Western blot analysis and immunohistochemistry. The relationship between H(2)S production/consumption and O(2) was examined in real time by use of amperometric H(2)S and O(2) sensors. H(2)S was produced by sea lion and cow lung homogenate in the absence of O(2), but it was rapidly consumed when O(2) was present. Furthermore, consumption of exogenous H(2)S by cow lung homogenate, PA smooth muscle cells, and heart mitochondria was O(2) dependent and exhibited maximal sensitivity at physiologically relevant Po(2) levels. These studies show that HVC is not an intrinsic property of PA and provide further evidence for O(2)-dependent H(2)S metabolism in O(2) sensing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2806212PMC
http://dx.doi.org/10.1152/ajpregu.00576.2009DOI Listing

Publication Analysis

Top Keywords

hypoxic pulmonary
8
hvc intrinsic
8
o2-sensing mechanism
8
pulmonary hypertension
8
sea lion
8
exogenous h2s
8
cow lung
8
lung homogenate
8
pulmonary
7
h2s
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!