A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quality of routine spirometry tests in Dutch general practices. | LitMetric

Quality of routine spirometry tests in Dutch general practices.

Br J Gen Pract

Department of Primary and Community Care, Asthma and COPD Research Unit, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands.

Published: December 2009

Background: Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care.

Aim: To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics.

Design Of Study: Analysis of routine spirometry test records.

Setting: Fifteen general practices which had a working agreement with a local hospital pulmonary function laboratory for spirometry assessment regarding test quality and interpretation.

Method: Spirometry tests were judged by a pulmonary function technician and a chest physician. Proportions of test adequacy were analysed using markers for manoeuvre acceptability and test reproducibility derived from the 1994 American Thoracic Society spirometry guideline. Associations between quality markers and age, sex, and severity of obstruction were examined using logistic regression.

Results: Practices performed a mean of four (standard deviation = 2) spirometry tests per week; 1271 tests from 1091 adult patients were analysed; 96.4% (95% confidence interval [CI] = 95.6 to 97.2) of all tests consisted of ≥3 blows. With 60.6% of tests, forced expiratory time was the marker with the lowest acceptability rate. An overall 38.8% (95% CI = 36.0 to 41.6) of the tests met the acceptability as well as reproducibility criteria. Age, sex, and severity of obstruction were associated with test quality markers.

Conclusion: The quality of routine spirometry tests was better than in previous reports from primary care research settings, but there is still substantial room for improvement. Sufficient duration of forced expiratory time is the quality marker with the highest rate of inadequacy. Primary care professionals should be aware of patient characteristics that may diminish the quality of their spirometry tests. Further research is needed to establish to what extent spirometry tests that are inadequate, according to stringent international expert criteria, result in incorrect clinical interpretations in general practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2784552PMC
http://dx.doi.org/10.3399/bjgp09X473088DOI Listing

Publication Analysis

Top Keywords

spirometry tests
28
routine spirometry
16
quality routine
12
test quality
12
spirometry
11
tests
11
quality
9
general practices
8
general practice
8
pulmonary function
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!