Purpose: To assess the literature on accuracy and clinical performance of computer technology applications in surgical implant dentistry.
Materials And Methods: Electronic and manual literature searches were conducted to collect information about (1) the accuracy and (2) clinical performance of computer-assisted implant systems. Meta-regression analysis was performed for summarizing the accuracy studies. Failure/complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 12-month proportions.
Results: Twenty-nine different image guidance systems were included. From 2,827 articles, 13 clinical and 19 accuracy studies were included in this systematic review. The meta-analysis of the accuracy (19 clinical and preclinical studies) revealed a total mean error of 0.74 mm (maximum of 4.5 mm) at the entry point in the bone and 0.85 mm at the apex (maximum of 7.1 mm). For the 5 included clinical studies (total of 506 implants) using computer-assisted implant dentistry, the mean failure rate was 3.36% (0% to 8.45%) after an observation period of at least 12 months. In 4.6% of the treated cases, intraoperative complications were reported; these included limited interocclusal distances to perform guided implant placement, limited primary implant stability, or need for additional grafting procedures.
Conclusion: Differing levels and quantity of evidence were available for computer-assisted implant placement, revealing high implant survival rates after only 12 months of observation in different indications and a reasonable level of accuracy. However, future long-term clinical data are necessary to identify clinical indications and to justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.
Download full-text PDF |
Source |
---|
Oral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Diseases, Helsinki University and Helsinki University Hospital, Helsinki, Finland.
Purpose: Preoperative virtual planning and osteosynthesis with patient-specific implants (PSIs) have become a quotidian approach to many maxillofacial elective surgery setups. When a process is well-organized, a similar approach can be harnessed to serve the needs of exact primary reconstructions, especially in midfacial trauma cases. PSI osteosynthesis of the mandible is, however, more challenging because a mirror technique of the facial sides is often unreliable due to inherent lack of symmetry, and movement of the mandible increases the risk of loosening of the osteosynthesis.
View Article and Find Full Text PDFBMC Oral Health
January 2025
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Disease, Department of Orthodontics, School of Stomatology, the Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shanxi, China.
Background: To improve the success rate of mini-implants, some surgical guides have been developed through digital technologies to achieve three-dimensional (3D) guided mini-implants insertion. However, there is no a surgical guide which can be applied for the insertion of infrazygomatic mini-implant. In this study, we introduced a two-trajectories surgical guide and investigated the success rate of infrazygomatic mini-implants under the guidance of the template.
View Article and Find Full Text PDFReprod Biomed Online
October 2024
Department of Biomedicine Experimental Biology Unit, Faculty of Medicine of the University of Porto, Porto, Portugal.; Instituto de Investigação e Inovação em Saúde (i3S), Porto, Portugal.. Electronic address:
Research Question: Does metformin reverse endometriosis-associated infertility?
Design: Endometriosis was induced by transplanting uterus fragments from B6CBAF1 mice into recipients of the same strain. The mice were divided into groups: endometriosis (End, n = 24), sham-operated (Sham, n = 12), endometriosis with metformin (0.5mg/ml) orally administered for 3 months (EndMet, n = 21) and sham-operated metformin-treated (ShamMet, n = 16).
Sci Rep
January 2025
Deutsches Herzzentrum der Charité, Department of Congenital and Pediatric Heart Surgery, Augustenburger Platz 1, 13353, Berlin, Germany.
Limited magnetic resonance imaging (MRI) data on autograft dilatation following the Ross procedure in congenital cohorts presents challenges in understanding its evolution and impact on clinical outcomes. This study, spanning from February 2003 to December 2022, included patients under 40 years at the time of the Ross procedure, with MRI follow-ups assessing dimensions at key aortic sites. Among 307 patients, 132 MRIs were analyzed from 76 individuals, revealing that autograft z-scores increase primarily with time post-procedure (Coef.
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
January 2025
Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Gauteng, South Africa.
The imaging of the live cochlea is a challenging task. Regardless of the quality of images obtained from modern clinical imaging techniques, the internal structures of the cochlea mainly remain obscured. Electrical impedance tomography (EIT) is a safe, low-cost alternative medical imaging technique with applications in various clinical scenarios.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!