A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A subcutaneous insulin pharmacokinetic model for computer simulation in a diabetes decision support role: validation and simulation. | LitMetric

Objective: The goal of this study was to validate a previously derived and identified physiological subcutaneous (SC) insulin absorption model for computer simulation in a clinical diabetes decision support role using published pharmacokinetic summary measures.

Methods: Validation was performed using maximal plasma insulin concentration (C(max)) and time to maximal concentration (t(max) pharmacokinetic summary measures. Values were either reported or estimated from 37 pharmacokinetic studies over six modeled insulin types. A validation comparison was made to equivalent pharmacokinetic summary measures calculated from model generated curves fitted to respective plasma insulin concentration data. The validation result was a measure of goodness of fit. Validation for each reported study was classified into one of four cases.

Results: Of 37 model fits, 22 were validated on both the C(max) and the t(max) summary measures. Another 6 model fits were partially validated on one measure only due to lack of reporting on the second measure with errors to reported or estimated ranges of <12%. Another 7 studies could not be validated on either measure because of inadequate reported clinical data. Finally, 2 separate model fits to data from the same study failed the validation with 90 and 71% error on t(max) only, which was likely caused by protocol-based error. No model fit failed the validation on both measures.

Conclusions: A previously derived and identified model was clinically validated for six insulin types using C(max) and t(max) summary measures from published pharmacokinetic studies. Hence, this article presents a clinically valid model that accounts for multiple nonlinear effects and six different types of SC insulin in a computationally modest form suitable for use in clinical decision support.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2769772PMC
http://dx.doi.org/10.1177/193229680800200418DOI Listing

Publication Analysis

Top Keywords

pharmacokinetic summary
12
summary measures
12
subcutaneous insulin
8
model computer
8
computer simulation
8
diabetes decision
8
decision support
8
support role
8
plasma insulin
8
insulin concentration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!