A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a clinical type 1 diabetes metabolic system model and in silico simulation tool. | LitMetric

Objectives: The goal of this study was to develop a system model of type 1 diabetes for the purpose of in silico simulation for the prediction of long-term glycemic control outcomes.

Methods: The system model was created and identified on a physiological cohort of virtual type 1 diabetes patients (n = 40). Integral-based identification was used to develop (n = 40) insulin sensitivity profiles.

Results: The n = 40 insulin sensitivity profiles provide a driving input for virtual patient trials using the models developed. The identified models have a median (90% range) absolute percentage error of 1.33% (0.08-7.20%). The median (90% range) absolute error was 0.12 mmol/liter (0.01-0.56 mmol/liter). The model and integral-based identification of SI captured all patient dynamics with low error, which would lead to more physiological behavior simulation.

Conclusions: A simulation tool incorporating n = 40 virtual patient data sets to predict long-term glycemic control outcomes from clinical interventions was developed based on a physiological type 1 diabetes metabolic system model. The overall goal is to utilize this model and insulin sensitivity profiles to develop and optimize self-monitoring blood glucose and multiple daily injection therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2769735PMC
http://dx.doi.org/10.1177/193229680800200312DOI Listing

Publication Analysis

Top Keywords

type diabetes
16
system model
16
insulin sensitivity
12
diabetes metabolic
8
metabolic system
8
silico simulation
8
simulation tool
8
long-term glycemic
8
glycemic control
8
integral-based identification
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!