Background: To determine if tibial positioning affects the external rotation of the tibia in a dial test for posterolateral rotatory instability combined with posterior cruciate ligament (PCL) injuries.

Methods: Between April 2007 and October 2007, 16 patients with a PCL tear and posterolateral rotatory instability were diagnosed using a dial test. The thigh-foot angle was measured at both 30 degrees and 90 degrees of knee flexion with an external rotation stress applied to the tibia in 2 different positions (reduction and posterior subluxation). The measurements were performed twice by 2 orthopedic surgeons.

Results: In posterior subluxation, the mean side-to-side difference in the thigh-foot angle was 11.56 +/- 3.01 degrees at 30 degrees of knee flexion and 11.88 +/- 4.03 degrees at 90 degrees of knee flexion. In the sequential dial test performed with the tibia reduced, the mean side-to-side difference was 15.94 +/- 4.17 degrees (p < 0.05) at 30 degrees of knee flexion and 16.88 +/- 4.42 degrees (p = 0.001) at 90 degrees of knee flexion. The mean tibial external rotation was 5.31 +/- 2.86 degrees and 6.87 +/- 3.59 degrees higher in the reduced position than in the posterior subluxation at both 30 degrees and 90 degrees of knee flexion.

Conclusions: In the dial test, reducing the tibia with an anterior force increases the ability of an examiner to detect posterolateral rotary instability of the knee combined with PCL injuries.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2766754PMC
http://dx.doi.org/10.4055/cios.2009.1.2.68DOI Listing

Publication Analysis

Top Keywords

degrees knee
24
knee flexion
20
dial test
16
degrees degrees
16
degrees
14
posterolateral rotatory
12
rotatory instability
12
external rotation
12
posterior subluxation
12
tibial positioning
8

Similar Publications

Background: This study investigated the influence of surgical alignment techniques on knee joint biomechanics during stair negotiation tasks. Our hypothesis was that a more personalized joint alignment would result in reduced medial knee loading biomechanics to negotiate the stairs.

Methods: There were 28 adults (14 mechanical alignments [MA], 14 kinematic alignment [KA]) who underwent total knee arthroplasty (TKA) at least one year post-operatively and performed five stair ascent and descent trials at their preferred velocities.

View Article and Find Full Text PDF

Introduction: Knee alignment significantly impacts the outcome of total knee arthroplasty (TKA). Understanding patient perceptions of their knee alignment in relation to objective measurements is essential to ensure optimal surgical outcomes and to meet patients' expectations. This study reports patients' perception of pre- and postoperative knee alignment in relation to radiographic alignment measurements.

View Article and Find Full Text PDF

Proximal tibiofibular joint detachment (PTFJD) is a fibular untethering procedure during lateral closing-wedge high tibial osteotomy (LCWHTO) for varus knee osteoarthritis. However, the PTFJD procedure is technically demanding, and confirmation of clear joint separation is not straightforward. The aim of this study was to compare the degree of completion and safety of PTFJD versus tibial-sided osteotomy (TSO); this latter procedure is our novel technique for fibular untethering during LCWHTO.

View Article and Find Full Text PDF

Multirotor drones are widely used in fields such as environmental monitoring, agricultural inspection, and package delivery, but they still face numerous challenges in durability and aerial operation capabilities. To address these issues, this paper presents a biomimetic leg-claw mechanism (LCM) inspired by the biomechanics of birds. The claw of the LCM adopts a bistable gripper design that can rapidly close through external impact or actively close via the coordination of internal mechanisms.

View Article and Find Full Text PDF

Instability remains one of the most common indications for revision after total knee arthroplasty. To gain a better understanding of how an implant will perform in vivo and support surgeons in selecting the most appropriate implant design for an individual patient, it is crucial to evaluate the implant constraint within clinically relevant ligament and boundary conditions. Therefore, this study investigated the constraint of three different implant designs (symmetrical implants with and without a post-cam mechanism and an asymmetrical medial-stabilized implant) under anterior-posterior shear forces and internal-external rotation moments at different flexion angles in human cadaveric knees using a six-degrees-of-freedom joint motion simulator.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!