Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate whether equine serum administered via a simulated subpalpebral lavage system (SPL) supports proliferation of Streptococcus zooepidemicus or Pseudomonas aeruginosa within the tubing.
Procedures: A sterile i.v. catheter with injection cap was inserted into sterilized silicone tubing (Mila). To mimic an SPL within the dorsal conjunctival fornix, the tubing was secured to an elevated platform. The tip of the tubing extended from the platform into a vial containing culture medium just inoculated with approximately 1.5 x 10(8) CFU/mL P. aeruginosa or S. zooepidemicus. To mimic administration of medication, the tubing was infused twice daily with equine serum, sterile saline (negative control), or culture medium (positive control) followed by air. Incubation was at 25 or 37 degrees C. At 24, 48, and 72 h postinoculation, samples were obtained for bacterial culture from one simulated SPL for each experimental variant. The following sections were cultured: (i) tubing tip previously submerged in the inoculated culture medium, (ii) tubing mid-section, and (iii) tip of the i.v. catheter. The experiment was performed in triplicate.
Results: Streptococcus zooepidemicus or P. aeruginosa were isolated from 100% of the tubing tips. Streptococcus zooepidemicus was isolated from one mid-section flushed with culture medium incubated at 37 degrees C. All other samples were negative for growth of the inoculated agents.
Conclusions: Streptococcus zooepidemicus and P. aeruginosa did not proliferate within silicone tubing infused with equine serum. These data suggest that topical serum can be safely administered through a superiorly placed SPL in clinical cases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1463-5224.2009.00725.x | DOI Listing |