Purpose: Measuring the anterior chamber diameter (AC) is important both for diagnostics and before ocular surgery. In clinical practice, horizontal AC diameter is usually estimated on the basis of measurements of corneal diameter (so-called white-to-white [WTW] distance). The usual method for selecting an appropriate size for an AC lens is to add 1 mm to WTW measurement. The purpose of this study was to compare AC diameter measured using ultrasound biomicroscopy (UBM) with WTW distance measured using digital photography in aphakic eyes.
Methods: The data were gathered prospectively from a nonrandomized consecutive series of aphakic patients. The examined group consisted of 23 eyes of 23 adult patients, mean age 71.17 years. WTW diameter was measured in the 3 o'clock and 9 o'clock meridian on a digital photograph. Internal horizontal AC diameter measurements were performed in the 3 o'clock and 9 o'clock meridian with the Sonomed Ultrabiomicroscopy device with a 50-MHz probe.
Results: Mean horizontal WTW diameter measured using digital photographs was 11.65+/-0.38 mm and mean horizontal internal AC diameter measured using UBM was 13.53+/-0.83 mm. A significant difference in mean WTW diameter measured using digital photography and UBM was found (Mann-Whitney U test, p<0.05). There was a significant correlation between these values (Spearman=0.70, p<0.001).
Conclusions: In order to obtain good and precise measurements of internal AC diameter, a method of direct visualization of the intraocular structures should be used. Despite the limits of a small case series, our results support the use of UBM technique for preoperative evaluation of the internal AC diameter and AC intraocular lens sizing in aphakic eyes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/112067211002000110 | DOI Listing |
J Assist Reprod Genet
January 2025
Department of Veterinary Medicine, University of Sassari, Via Vienna 2, Sassari, Italy.
Purpose: This study aimed to evaluate the effectiveness of single versus group culture strategies for cumulus-oocyte complexes (COCs) derived from early antral follicles (EAFs), with the goal of optimizing culture conditions to increase oocyte availability for assisted reproductive technologies.
Methods: COCs isolated from EAFs (350-450 µm) from sheep ovaries were cultured in TCM199 medium supplemented with 0.15 µg/mL Zn as zinc sulfate, 10 IU/mL FSH, 10 ng/mL estradiol, 50 ng/mL testosterone, 50 ng/mL progesterone, and 5 µM Cilostamide.
Surg Radiol Anat
January 2025
Faculty of Dental Medicine, University of Porto, Porto, Portugal.
Purpose: The greater palatine foramen (GPF) represents the inferior opening of the greater palatine canal and is located posterolaterally on both sides of the hard palate. The aim of this study is to morphometrically characterise the GPF and to determine its anatomical relationships in a Portuguese population.
Methods: A retrospective study was performed based on the clinical records which included all permanent teeth erupted and a cone beam computed tomography (CBCT) of the entire maxilla.
Am J Physiol Heart Circ Physiol
January 2025
Department of Physiology and Biophysics, Dalhousie University, Halifax, NS.
This study investigated the sexual dimorphism in right ventricle (RV) remodeling in right heart failure susceptible Fischer CDF rats using the pulmonary artery banding (PAB) model. Echocardiography and hemodynamic measurements were performed in adult male and female Fischer CDF rats at 1- or 2-weeks post-PAB. RV systolic pressure and RV hypertrophy were significantly elevated in PAB rats compared to sham control at 1- and 2-weeks post-PAB; however, no differences were observed between male and female rats.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
August 2024
In this paper, we explore the impact of exposure time on optical-phase measurements collected on light that has propagated through atmospheric-optical turbulence. We model the exposure time by phase averaging over a convective distance, and we quantify the associated impact of imposing an exposure time using the piston- and tilt-removed phase variance. We accomplish this analysis through the development of an analytic solution and wave-optics simulations.
View Article and Find Full Text PDFJ Contemp Dent Pract
October 2024
Department of Crown and Bridge, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt.
Aim: To assess hard as well as soft peri-implant tissues within cases having two lost adjacent anterior teeth treated through placing either two implants with two separate crowns or only an implant along with a crown with a cantilever, and evaluating the effect of polyetheretherketone (PEEK) restoration on cantilever design up to 18 months after functional loading.
Materials And Methods: Twenty-seven participants (15 males and 12 females; mean age, 38.6 years; range 20-50 years) with missing two adjacent anterior teeth were treated with implant system (Flotecno implant system, Italy).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!