Minimizing specimen length in elastic testing of end-constrained cancellous bone.

J Mech Behav Biomed Mater

Department of Mechanical and Materials Engineering, Queen's University, Kingston, Ontario, Canada.

Published: January 2010

End-constraint is needed when performing tensile and compressive testing of cancellous bone so that frictional and structural end-effects are minimized and the mechanical properties are not underestimated. Since many end-constrained testing techniques are limited to certain sites and species by the large specimen sizes required, reductions in overall specimen length would be advantageous. The following study examines the effect of specimen gauge length and aspect ratio on the elastic tensile testing of cancellous bone from the bovine femoral condyle. Three different nominal gauge lengths (10, 16, 22 mm) were examined at two different diameters (5.1, 10.7 mm) which bound the range typically used for cancellous bone testing. No effect of gauge length or aspect ratio was observed, but evidence of a diameter effect was noted. Three-dimensional finite element method (FEM) models confirmed the experimental observations and demonstrated that an overestimation of modulus begins to occur for specimens shorter than 10 mm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2009.02.001DOI Listing

Publication Analysis

Top Keywords

cancellous bone
16
specimen length
8
testing cancellous
8
gauge length
8
length aspect
8
aspect ratio
8
testing
5
minimizing specimen
4
length
4
length elastic
4

Similar Publications

Leptin increases focal inflammation and osteolysis induced by polyethylene particles in leptin-deficient ob/ob mice suggesting the adipokine, an important immune modulator, contributes to orthopedic implant failure. Focal inflammation leads to bone loss at distant skeletal sites, and it is plausible that leptin also contributes to this response. We tested this possibility in 6-week-old female ob/ob mice (6-8/group) by evaluating bone architecture, turnover, and gene expression 12 days following surgical placement of polyethylene particles over calvaria.

View Article and Find Full Text PDF

Background/purpose: The use of finite element (FE) analysis in implant biomechanics offers many advantages over other approaches in simulating the complexity of clinical situations. The aim of this study was to perform an optimization analysis of dental implants with different thread designs in three types of bone quality.

Materials And Methods: The three-dimensional FE model of a mandibular bone block with a screw-shaped dental implant and superstructure was simulated.

View Article and Find Full Text PDF

Background: Ankle fractures continue to increase in incidence and severity in an older, more challenging geriatric population. Medial malleolus fixation with partially threaded cancellous 4.0-mm screws, a common fixation method, has been shown to fail due to pullout strength.

View Article and Find Full Text PDF

Simulation analysis of surgical neck fractures of the humerus related to bone degeneration.

Comput Methods Biomech Biomed Engin

January 2025

Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, China.

The most common type of proximal humerus fracture is surgical neck fracture. The purpose of this paper is to study the mechanical mechanism and the effect of bone degeneration on humeral surgical neck fractures. The right humerus finite element models were established based on CT computed tomography.

View Article and Find Full Text PDF

To clarify the roles and mechanisms of adipokine chemerin in exercise-induced bone improvements in type 2 diabetes mellitus (DM) mice and mice fed on high fat diet (HFD). DM mice were established by HFD+streptozotocin injection, exogenous chemerin was supplemented prior to running, and found that exogenous chemerin reversed 6-week exercise-induced improvements in cancellous bone parameters in DM mice. While adipose-specific chemerin knockout improved microstructure and mass of cancellous bone in HFD mice and further increased exercise-induced bone improvements, accompanied with promoted osteogenesis and inhibited osteoclasis represented as the changes of RANKL, M-CSF, Runx2, Osterix, OPG, ALP and CTSK.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!