A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MR angiography of infrapopliteal arteries in patients with peripheral arterial occlusive disease by using Gadofosveset at 3.0 T: diagnostic accuracy compared with selective DSA. | LitMetric

Purpose: To prospectively compare the diagnostic accuracy of steady-state, high-spatial-resolution magnetic resonance (MR) angiography of the lower leg, performed with a blood pool contrast agent, with selective digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial disease.

Materials And Methods: Local ethics committee approval and written informed consent were obtained. In a nonrandomized trial, selective DSA and MR angiography were performed at 3.0 T with a blood pool contrast agent on 22 calves in 20 patients (mean age, 69.4 years +/- 11.3 [standard deviation]), 16 men (mean age, 67.8 years +/- 12.4) and four women (mean age, 75.6 years +/- 3.6 years), to evaluate 352 arterial segments. DSA and MR angiography were performed within 24 hours of each other and directly compared by three experienced, blinded radiologists by using high-spatial-resolution steady-state MR angiograms. Consensus reading for both DSA and MR angiography served as the reference standard.

Results: MR angiography was successful and occurred without serious adverse events in all patients. Seven significantly stenosed and 40 occluded segments were rated equally in both modalities. In three cases, the tibial arteries were shown to be occluded or significantly stenosed at DSA but appeared normal or significantly stenosed at MR angiography. The respective average segment sensitivity, specificity, and accuracy were 98.3% (59 of 60), 98% (113.7 of 116), and 98.1% (172.7 of 176) for DSA and 100% (60 of 60), 100% (116 of 116), and 100% (176 of 176) for MR angiography. Steady-state MR angiography was especially useful for the distal peroneal artery and the proximal anterior tibial artery.

Conclusion: MR angiography performed with blood pool agents has an accuracy comparable with that of selective DSA in the lower leg but with less risk involved. Steady-state imaging performed with blood pool agents facilitates evaluation of MR angiography of infrapopliteal arteries.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2533081627DOI Listing

Publication Analysis

Top Keywords

performed blood
16
blood pool
16
angiography
12
selective dsa
12
dsa angiography
12
angiography performed
12
years +/-
12
angiography infrapopliteal
8
infrapopliteal arteries
8
peripheral arterial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!