A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Occipital nerve stimulator lead pathway length changes with volunteer movement: an in vitro study. | LitMetric

Background: Occipital nerve stimulation is a modality reserved for refractory headache disorders. Leads (wires) are inserted subcutaneously in the occipital region to stimulate the distal C1-3 nerves; lead migration may result from repeated mechanical forces on the lead associated with patient movement. The primary aim of this study was to determine implantation pathways associated with the least pathway length change secondary to body movement in an in vitro model of an occipital stimulator system.

Methods: After institutional review board approval, 10 volunteers were recruited. The expected pathway of an occipital stimulator system was identified and measured externally, and then changes in pathway length were measured during various volunteer movements, including neck and low back flexion, extension, rotation, and lateral flexion. The pathways studied included those that connect internal pulse generators in the gluteal, low abdominal, and infraclavicular regions to occipital leads inserted via a cervical or retromastoid approach.

Results: The flexion/extension pathway length changes associated with midline occipital and retromastoid sites to the infraclavicular site were significantly less than those pathways to the periscapular site. Also, the abdominal site was associated with less pathway length change during flexion/extension than the gluteal site.

Conclusions: Internal pulse generators in sites other than the buttock, including infraclavicular or low abdomen, may be associated with lower lead migration risk. There are many considerations when selecting insertion sites and lead pathways for occipital nerve stimulation. Implanters and patients may consider these results when contemplating surgical approaches to this challenging form of peripheral nerve stimulation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1533-2500.2009.00328.xDOI Listing

Publication Analysis

Top Keywords

pathway length
20
occipital nerve
12
nerve stimulation
12
occipital
8
length changes
8
movement vitro
8
lead migration
8
associated pathway
8
length change
8
occipital stimulator
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!