Background: In areas where non-falciparum malaria is common rapid diagnostic tests (RDTs) capable of distinguishing malaria species reliably are needed. Such tests are often based on the detection of parasite lactate dehydrogenase (pLDH).

Methods: In Dawei, southern Myanmar, three pLDH based RDTs (CareStart Malaria pLDH (Pan), CareStart Malaria pLDH (Pan, Pf) and OptiMAL-IT)were evaluated in patients presenting with clinically suspected malaria. Each RDT was read independently by two readers. A subset of patients with microscopically confirmed malaria had their RDTs repeated on days 2, 7 and then weekly until negative. At the end of the study, samples of study batches were sent for heat stability testing.

Results: Between August and November 2007, 1004 patients aged between 1 and 93 years were enrolled in the study. Slide microscopy (the reference standard) diagnosed 213 Plasmodium vivax (Pv) monoinfections, 98 Plasmodium falciparum (Pf) mono-infections and no malaria in 650 cases. The sensitivities (sens) and specificities (spec), of the RDTs for the detection of malaria were- CareStart Malaria pLDH (Pan) test: sens 89.1% [CI95 84.2-92.6], spec 97.6% [CI95 96.5-98.4]. OptiMal-IT: Pf+/- other species detection: sens 95.2% [CI95 87.5-98.2], spec 94.7% [CI95 93.3-95.8]; non-Pf detection alone: sens 89.6% [CI95 83.6-93.6], spec 96.5% [CI95 94.8-97.7]. CareStart Malaria pLDH (Pan, Pf): Pf+/- other species: sens 93.5% [CI95 85.4-97.3], spec 97.4% [95.9-98.3]; non-Pf: sens 78.5% [CI95 71.1-84.4], spec 97.8% [CI95 96.3-98.7]. Inter-observer agreement was excellent for all tests (kappa > 0.9). The median time for the RDTs to become negative was two days for the CareStart Malaria tests and seven days for OptiMAL-IT. Tests were heat stable up to 90 days except for OptiMAL-IT (Pf specific pLDH stable to day 20 at 35 degrees C).

Conclusion: None of the pLDH-based RDTs evaluated was able to detect non-falciparum malaria with high sensitivity, particularly at low parasitaemias. OptiMAL-IT performed best overall and would perform best in an area of high malaria prevalence among screened fever cases. However, heat stability was unacceptable and the number of steps to perform this test is a significant drawback in the field. A reliable, heat-stable, highly sensitive RDT, capable of diagnosing all Plasmodium species has yet to be identified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2774865PMC
http://dx.doi.org/10.1186/1475-2875-8-241DOI Listing

Publication Analysis

Top Keywords

carestart malaria
20
malaria pldh
16
pldh pan
16
malaria
14
[ci95
9
parasite lactate
8
rapid diagnostic
8
diagnostic tests
8
non-falciparum malaria
8
heat stability
8

Similar Publications

Background: One of the main challenge for controlling the morbidity and mortality related to malaria is the absence of reliable treatment and precise diagnostic tools in malaria-prone regions. Despite the number of diagnostic techniques used, and inconsistent results were found from previous studies. The aim of this study is to assess the effectiveness of 18S nested PCR(Polymerase Chain Reaction),microscopy, and CarestartTMpf/pan RDT(Rapid Diagnostic Tests) as malaria diagnostic methods using Microscopy and 18S nested PCR as reference techniques.

View Article and Find Full Text PDF

Subclinical malaria among pregnant women living in refugee settlements in Northern Uganda.

Ther Adv Infect Dis

November 2024

Department of Environmental Sciences and Engineering, the University of North Carolina at Chapel Hill, 0300 Michael Hooker Research Center, 135 Dauer Drive, Campus Box # 7431, Chapel Hill, NC 27599, USA.

Background: Malaria during pregnancy contributes to significant perinatal morbidity and mortality, accounting for almost 25% of global maternal mortality. However, the epidemiology and risk factors for subclinical malaria among pregnant women living in refugee settlements is poorly understood.

Objective: To determine the prevalence and predictors of subclinical malaria among pregnant women in refugee settlements in Northern Uganda.

View Article and Find Full Text PDF

Background: Data on the asymptomatic burden of malaria in endemic areas is essential for Ghana's malaria elimination efforts. Consequently, the situation of asymptomatic malaria in the Fanteakwa South District (FSD) is determined in this study. The FSD is predominantly forested with more rural than peri-urban communities.

View Article and Find Full Text PDF

Background: To interrupt residual malaria transmission and achieve successful elimination of Plasmodium falciparum in low-transmission settings, the World Health Organization (WHO) recommends the administration of a single dose of 0.25 mg/kg (or 15 mg/kg for adults) primaquine (PQ) combined with artemisinin-based combination therapy (ACT), without glucose-6-phosphate dehydrogenase (G6PD) testing. However, due to the risk of haemolysis in patients with G6PD deficiency (G6PDd), PQ use is uncommon.

View Article and Find Full Text PDF

Malaria rapid diagnostic test (mRDT) kit is one of the techniques for diagnosing malaria. Due to its inherent advantages over the microscopy technique, several brands of the kit have flooded malaria endemic countries, without prior in-country evaluation. Two of such mRDT kits are Oscar (India) and Standard Q (Korea Republic).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!