A bioanalytical test battery was used to monitor the removal efficiency of organic micropollutants during advanced wastewater treatment in the South Caboolture Water Reclamation Plant, Queensland, Australia. This plant treats effluent from a conventional sewage treatment plant for industrial water reuse. The aqueous samples were enriched using solid-phase extraction to separate some organic micropollutants of interest from metals, nutrients and matrix components. The bioassays were chosen to provide information on groups of chemicals with a common mode of toxic action. Therefore they can be considered as sum indicators to detect certain relevant groups of chemicals, not as the most ecologically or human health relevant endpoints. The baseline toxicity was quantified with the bioluminescence inhibition test using the marine bacterium Vibrio fischeri. The specific modes of toxic action that were targeted with five additional bioassays included aspects of estrogenicity, dioxin-like activity, genotoxicity, neurotoxicity, and phytotoxicity. While the accompanying publication discusses the treatment steps in more detail by drawing from the results of chemical analysis as well as the bioanalytical results, here we focus on the applicability and limitations of using bioassays for the purpose of determining the treatment efficacy of advanced water treatment and for water quality assessment in general. Results are reported in toxic equivalent concentrations (TEQ), that is, the concentration of a reference compound required to elicit the same response as the unknown and unidentified mixture of micropollutants actually present. TEQ proved to be useful and easily communicable despite some limitations and uncertainties in their derivation based on the mixture toxicity theory. The results obtained were reproducible, robust and sensitive. The TEQ in the influent ranged in the same order of magnitude as typically seen in effluents of conventional sewage treatment plants. In the initial steps of the treatment chain, no significant degradation of micropollutants was observed, and the high levels of dissolved organic carbon probably affected the outcome of the bioassays. The steps of coagulation/flocculation/dissolved air flotation/sand filtration and ozonation decreased the effect-based micropollutant burden significantly.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.watres.2009.09.025 | DOI Listing |
Nanotechnology
January 2025
University of Arkansas, Fayetteville, AR, Fayetteville, Arkansas, 72701-4002, UNITED STATES.
Over the past few decades, significant efforts have been dedicated to advancing technologies for the removal of micropollutants from water. Achieving complete pure water with a single treatment process is challenging and nearly impossible. One promising approach among various alternatives is adopting hybrid technology, which is considered as a win-win technology.
View Article and Find Full Text PDFIntegr Environ Assess Manag
January 2025
GhEnToxLab, Department of Animal Science and Aquatic Ecology, Ghent University, Ghent, Belgium.
This study investigates the ecological risks posed by organic micropollutants (OMPs) in wastewater treatment plant (WWTP) effluents in Flanders, Belgium based on single-compound risk characterization. Utilizing a five-year monitoring dataset from the Flemish Environment Agency (VMM) and employing seven ecological threshold values (ETV) types, this research characterizes the risk of 207 OMPs, including pharmaceuticals, pesticides, industrial chemicals, and other pollutants. Several OMPs persist in effluents at concentrations that pose significant ecological risks after secondary and tertiary treatment processes in the region of Flanders (Belgium).
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Centre for the Environment, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India; Chemical Engineering Department, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India. Electronic address:
Globalization resulted in technological advancement, and urban population growth. Consequently, pollution emerged as an imminent risk to the survival of all species on Earth. Consequently, on a worldwide basis, sustainability become a major issue for legislators.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
January 2025
Bio-Microfluidics Lab, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology, Tehran, Iran.
Water pollution, driven by a variety of enduring contaminants, poses considerable threats to ecosystems, human health, and biodiversity, highlighting the urgent need for innovative and sustainable treatment approaches. Ozone-based advanced oxidation processes (AOPs) have demonstrated significant efficacy in breaking down stubborn pollutants, such as organic micropollutants and pathogens, that are not easily addressed by traditional treatment techniques. This review offers an in-depth analysis of ozonation mechanisms, covering both the direct oxidation by ozone and the indirect reactions facilitated by hydroxyl radicals, emphasizing their effectiveness and adaptability across various wastewater matrices.
View Article and Find Full Text PDFSci Total Environ
February 2025
Department of Civil Engineering and Architecture, University of Catania, Viale A. Doria 6, Catania, Italy. Electronic address:
This study investigated the applicability of a protein-like fluorescence sensor for wastewater quality monitoring. Several wastewater matrices, including raw, primary, secondary and tertiary effluents from three different wastewater treatment plants were used. Furthermore, the sensor was tested for the monitoring of quaternary effluent in a pilot scale plant installed downstream of a water reuse facility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!