A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Delayed setting and hygroscopic linear expansion of three gypsum products used for cast articulation. | LitMetric

Delayed setting and hygroscopic linear expansion of three gypsum products used for cast articulation.

J Prosthet Dent

Department of Prosthodontics and Operative Dentistry, Division of Graduate and Postgraduate Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass., USA.

Published: November 2009

Statement Of Problem: Wetting of the set gypsum product used for cast articulation may result in additional expansion.

Purpose: The purpose of this study was to evaluate the linear expansion of 2 type II and 1 type III gypsum products with and without addition of water after setting, over a time period of 120 hours.

Material And Methods: The gypsum products tested in this study were Model Plaster, Lab Plaster, and Mounting Stone. All materials were hand mixed for 5 seconds and mechanically mixed under vacuum for another 15 seconds. The mixes were poured into a linear expansion-measuring instrument (n=20). Half of the specimens were wet with 25 ml of water immediately after the setting time recommended by the manufacturer, and at all time intervals, immediately after data collection. No treatment was performed on the remainder of the specimens. The expansion values were recorded with an expansion-measuring device over a period of 120 hours. Collected data were subjected to a 2-way repeated-measures analysis of variance (ANOVA) (alpha=.05).

Results: The highest expansion values for all gypsum products were recorded at 96 and 120 hours. No significant difference in setting expansion values was recorded between these 2 time intervals for any of the materials and treatment conditions (dry vs. wet). Mean expansion values ranged between 0.08% +/-0.06% for dry Mounting Stone specimens at 15 minutes, to 0.57% +/- 0.02% for wet Lab Plaster specimens at 96 and 120 hours. Significant differences (P<.001) between different mounting gypsum products and time were identified. A significant difference between wet and dry specimens was not observed.

Conclusions: The expansion of all gypsum products used for articulation purposes was complete at 96 hours. The type III gypsum product demonstrated lower mean expansion values than type II products. Time and material were more important factors than the dry/wet condition when measuring total expansion values. Type II gypsum products demonstrated 80% or more of the total expansion values in the first 45 minutes, while type III stone demonstrated the same expansion after 24 hours.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0022-3913(09)60181-5DOI Listing

Publication Analysis

Top Keywords

gypsum products
16
expansion values
16
120 hours
12
linear expansion
8
cast articulation
8
water setting
8
setting time
8
period 120
8
lab plaster
8
mounting stone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!