A parallel second-order adaptive mesh algorithm for incompressible flow in porous media.

Philos Trans A Math Phys Eng Sci

Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.

Published: November 2009

In this paper, we present a second-order accurate adaptive algorithm for solving multi-phase, incompressible flow in porous media. We assume a multi-phase form of Darcy's law with relative permeabilities given as a function of the phase saturation. The remaining equations express conservation of mass for the fluid constituents. In this setting, the total velocity, defined to be the sum of the phase velocities, is divergence free. The basic integration method is based on a total-velocity splitting approach in which we solve a second-order elliptic pressure equation to obtain a total velocity. This total velocity is then used to recast component conservation equations as nonlinear hyperbolic equations. Our approach to adaptive refinement uses a nested hierarchy of logically rectangular grids with simultaneous refinement of the grids in both space and time. The integration algorithm on the grid hierarchy is a recursive procedure in which coarse grids are advanced in time, fine grids are advanced multiple steps to reach the same time as the coarse grids and the data at different levels are then synchronized. The single-grid algorithm is described briefly, but the emphasis here is on the time-stepping procedure for the adaptive hierarchy. Numerical examples are presented to demonstrate the algorithm's accuracy and convergence properties and to illustrate the behaviour of the method.

Download full-text PDF

Source
http://dx.doi.org/10.1098/rsta.2009.0160DOI Listing

Publication Analysis

Top Keywords

total velocity
12
incompressible flow
8
flow porous
8
porous media
8
coarse grids
8
grids advanced
8
grids
5
parallel second-order
4
adaptive
4
second-order adaptive
4

Similar Publications

The main advantages of microneedles are precise drug delivery through human skin, minimal tissue damage and painlessness. We conducted structural analysis and skin puncture studies of hollow microneedles using ANSYS for three materials: Hafnium Dioxide (HfO), Polyglycolic acid (PGA) and Polylactic acid (PLA). Firstly, we selected three lengths, three tip diameters and three base diameters to conduct a L(3) orthogonal experiment.

View Article and Find Full Text PDF

Background: Preclinical Alzheimer's disease may be linked to impaired cerebral amyloid clearance. We aim to obtain dynamic parameters of cortical and ventricular clearance of C-PIB and compare them with CSF amyloid values in a population of healthy volunteers.

Method: We evaluated 8 healthy volunteers (4 men and mean age: 64.

View Article and Find Full Text PDF

MIL-53(Al)-derived bimetallic Pd-Co catalysts for the selective hydrogenation of 1,3-butadiene at low temperature.

Sci Rep

January 2025

School of Chemistry & Chemical Engineering and Environmental Engineering, Weifang University, Weifang, 261061, China.

Selective hydrogenation of 1,3-butadiene is a crucial industrial process for the removing of 1,3-butadiene, a byproduct of butene production. Developing catalysts with high catalytic performance for the hydrogenation of 1,3-butadiene at low temperatures has become a research hotspot. In this study, bimetallic Pd-Co catalysts supported on AlO derived from MIL-53(Al) at various calcination temperatures were synthesised via the co-impregnation method.

View Article and Find Full Text PDF

The long-term hypercortisolemia of Cushing disease (CD) may lead to hemodynamic disorders by increasing subclinical cardiac and vascular dysfunction. The purpose of this observational cohort study was to assess the relationship between hemodynamic parameters evaluated via impedance cardiography (ICG) and echocardiographic parameters reflecting left ventricular function in 54 patients newly diagnosed with CD. The parameters assessed via ICG included stroke volume index (SI), cardiac index (CI), acceleration index (ACI), velocity index (VI), systemic vascular resistance index (SVRI), total artery compliance index (TACI).

View Article and Find Full Text PDF

Introduction: The recently proposed cerebral small vessel disease (CSVD) score system may help to capture the overall burden of CSVD. This study aimed to investigate the associations between carotid artery ultrasound features and the burden score and cognitive performance of CSVD patients.

Methods: This is a cross-sectional analysis of an ongoing prospective study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!