Background: Rotating hinge knee prostheses are indicated in revisions especially when major ligament laxity or substantial AP deformities are present. These situations make ligament balancing difficult with less constrained design implants. Despite its use for nearly 50 years, this type of prosthesis continues to have a poor reputation due to a high complication rate.
Hypothesis: Complications are frequent after this type of arthroplasty and the complication rate is similar in primary or revision arthroplasties. The objective of this study is to report the medium-term results of these implants and determine the eventual predictive factors of complications in order to refine operative indications.
Material And Methods: In this retrospective study of patients operated on between 1998 and 2006, 85 Endo-Modell (Link) rotating hinge knee prostheses had been used in 61 females and 24 males. The mean age at surgery was 72.4 years (range, 32-92 years). Fifty-two arthroplasties were primary and 33 were revisions either for loosening (24) or deep infections (9). The mean follow-up was 36 months+/-22 (range, 0-75 months).
Results: Complications were observed in 24 patients (28.2%): nine deep infections, four patellar complications, and three cases of aseptic loosening. No significant difference was found between the primary arthroplasties and the revisions regarding all complication types. A significant relation was established between the occurrence of a complication and presence of several associated comorbidity factors (obesity, heart disease, diabetes, etc.).
Discussion: The use of this type of implant carries a high risk of complications, higher than the one pertaining to unconstrained design prostheses; this fact is noted irrespective of the surgical indication and other comparison elements. The leading criteria to poor functional results appear to be the indication (gonarthrosis with substantial ligament laxity at primary surgery) and the number of associated comorbidities. These prostheses should therefore be restricted to selected indications, notably in view of the fact that less constrained prostheses give superior outcomes.
Level Of Evidence: Level IV. Retrospective therapeutic study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2009.07.013 | DOI Listing |
Sci Robot
January 2025
Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA.
Aerial insects are exceptionally agile and precise owing to their small size and fast neuromotor control. They perform impressive acrobatic maneuvers when evading predators, recovering from wind gust, or landing on moving objects. Flapping-wing propulsion is advantageous for flight agility because it can generate large changes in instantaneous forces and torques.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
December 2024
Gavin Herbert Eye Institute, Ophthalmology Department, University of California, Irvine, School of Medicine. 850 Health Sciences Rd, Irvine, CA 92617, USA.
This video demonstrates two surgical cases where autologous Tenon grafts are used to shut down leaking trabeculectomies. Variations in this technique with a rotational graft and a hinge graft are explored.
View Article and Find Full Text PDFBackground In low-income countries, clinicians trained through a context-specific trauma surgery fellowship program (TFP) can help reduce injury-related mortality to levels closer to those observed in higher-resource settings. Successful implementation, however, hinges on buy-in from local clinicians. We therefore assessed clinician support for a potential TFP in Uganda, considering perceived need, curricular recommendations, barriers, and motivating factors.
View Article and Find Full Text PDFSci Rep
December 2024
College of Information Engineering, SuQian University, SuQian, 223800, China.
The safety and reliability of rotating machinery hinge significantly on the proper functioning of rolling bearings. In the last few years, there have been significant advances in the algorithms for intelligent fault diagnosis of bearings. However, the vibration signals collected by machines are inevitably affected by irrelevant noise because of the complex working environments of bearings.
View Article and Find Full Text PDFAnat Rec (Hoboken)
December 2024
Biology Department, Northland Pioneer College, Holbrook, Arizona, USA.
Nothronychus graffami was a large therizinosaur represented by a single well-preserved individual from the Turonian Tropic Shale of southern Utah. It is characterized by an enlarged abdomen, small tail, and an extensively pneumatized axial skeleton, and is frequently regarded as herbivorous. Given the overall tail reduction and the development of a wide fused synsacrum with widely spaced acetabulae, it is reconstructed with an anteriorly rotated femur and a displaced resting ground reaction force anterior to the center of mass.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!