A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of phenylalanine and tyrosine in plasma and dried blood samples using HPLC with fluorescence detection. | LitMetric

Determination of phenylalanine and tyrosine in plasma and dried blood samples using HPLC with fluorescence detection.

J Chromatogr B Analyt Technol Biomed Life Sci

Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Strossova 239, 530 03 Pardubice, Czech Republic.

Published: November 2009

The determination of phenylalanine and tyrosine is presently the most reliable direct approach to the diagnosis of phenylketonuria. An HPLC method for the simultaneous measurement of phenylalanine and tyrosine in samples of dried blood spots and plasma has been developed and evaluated. We have used an inherent fluorescence of both phenylalanine and tyrosine. For the separation, a reverse-phase column LiChroCart 125-4, Purospher RP-18e, 5microm, was used. The mixture of ethanol and deionized water (5:95, v/v) was used as a mobile phase. Analytical performance of this method is satisfactory for both phenylalanine and tyrosine: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries from spiked plasma and blood samples were between 92.0 and 102.9%. The limit of detection was 10.0 and 5.0micromol/L, respectively. The preliminary reference ranges of phenylalanine and tyrosine in a group of newborns are 69.3+/-13.1 and 42.7+/-12.9micromol/L, in a group of blood donors are 68.4+/-9.9 and 52.1+/-10.9micromol/L. The presented method is inexpensive and suitable for diagnosis of phenylketonuria.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2009.09.045DOI Listing

Publication Analysis

Top Keywords

phenylalanine tyrosine
24
determination phenylalanine
8
dried blood
8
blood samples
8
diagnosis phenylketonuria
8
tyrosine
6
phenylalanine
5
tyrosine plasma
4
plasma dried
4
blood
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!