Literature review and anecdotal evidence appears to suggest a variation in the number of imaging projections used to demonstrate recent injury to the wrist, dependent on which Accident and Emergency (A&E) radiology department a patient attends. Some departments routinely undertake two projections (dorsi-palmar and lateral) whilst others include a dorsi-palmar oblique projection. The aim of this research was to assess if the inclusion of the additional projection altered the sensitivity of bony injury detection. Four readers reported 250 anonymous image sets, initially of two projections, and then at a later date, reported the same two projections along with the additional third projection, however, they did not have access to their previous reports. The readers identified 4.4% more fractures with the additional projection. Additionally, 2.8% of the fractures had not been identified by any reader on two projections, but were identified by all readers with three projections. Statistical analysis using chi-square test identified a statistical difference in the bone injury detection sensitivity (p < 0.001) when including a third projection. Kappa statistics assessed inter-observer correlation which increased from 0.68 on two projections to 0.78 on three projections. The number of equivocal reports reduced to less than half when the third projection was included. There is an increase in the sensitivity of bone injury identification with the additional projection, which is likely to be of significance to patients and A&E departments, with obviously beneficial social and financial implications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10140-009-0836-4DOI Listing

Publication Analysis

Top Keywords

additional projection
12
third projection
12
projections
8
injury detection
8
three projections
8
bone injury
8
projection
7
trauma adult
4
adult wrist
4
wrist radiographic
4

Similar Publications

Corticocortical (CC) projections in the visual system facilitate hierarchical processing of sensory information. In addition to direct CC connections, indirect cortico-thalamo-cortical (CTC) pathways through the pulvinar nucleus of the thalamus can relay sensory signals and mediate cortical interactions according to behavioral demands. While the pulvinar connects extensively to the entire visual cortex, it is unknown whether transthalamic pathways link all cortical areas or whether they follow systematic organizational rules.

View Article and Find Full Text PDF

Rotational spectroscopy is an excellent tool for structure determination, which can provide additional insights into local electronic structure by investigating the hyperfine pattern due to nuclear quadrupole coupling. Jet-cooled molecules are good experimental benchmark targets for electronic structure calculations, as they are free of environmental effects. We report the rotational spectra of 2-chlorobenzaldehyde, 3-chlorobenzaldehyde, and 4-chlorobenzaldehyde, including a complete experimental description of the nuclear quadrupole coupling constants, which were previously not experimentally determined.

View Article and Find Full Text PDF

Background And Aims: The COVID-19 pandemic led to changes in alcohol consumption in England. Evidence suggests that one-fifth to one-third of adults increased their alcohol consumption, while a similar proportion reported consuming less. Heavier drinkers increased their consumption the most and there was a 20% increase in alcohol-specific deaths in England in 2020 compared with 2019, a trend continuing through 2021 and 2022.

View Article and Find Full Text PDF

The burden of cirrhosis and chronic liver disease is growing, yet there is a projected worsening deficit in hepatology providers. As such, cirrhosis and liver disease have been important inclusions within the core curricula of Internal Medicine. Formal assessments of provider preparedness resulting from the curriculum are lacking though.

View Article and Find Full Text PDF

Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal-to-noise ratio is limited by the field strength and k-space sampling speed is limited by a lower specification gradient system.

Methods: We adapted the three-dimensional spiral projection imaging MR fingerprinting approach to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!