Optical injection locking and optical phase-lock loops have been used for laser synchronization. The use of a combined optical injection locking and phase-lock loop system is proposed here. We have taken into account the modification of the slave laser phase response induced by the injection locking to calculated the phase-error signal spectrum and the phase-error variance for an optical injection locking and phase-lock system. They show that this system presents both a wide locking range, given by the optical injection locking action, and a low phase error for low frequencies, given by the optical phase-lock loop action. These results can improve the system tracking capability and decrease the final phase-error variance compared with those in isolated systems.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.19.000004DOI Listing

Publication Analysis

Top Keywords

injection locking
24
optical injection
20
locking phase-lock
12
phase-lock loop
12
optical phase-lock
8
phase-error variance
8
optical
7
locking
7
phase-lock
5
injection
5

Similar Publications

Acoustic frequency comb generation on a composite diamond/silicon microcantilever in ambient air.

Microsyst Nanoeng

January 2025

Institute of Novel Semiconductors, State Key Laboratory of Crystal Materials, Shandong University, 27 South Shanda Road, Shandong, 250100, P. R. China.

Acoustic frequency combs (AFCs) contain equidistant coherent signals with unconventional possibilities on metrology. Previously, implementation of AFCs on mechanical microresonators with large air damping loss is difficult, which restricted their atmospheric applications. In this work, we explore the potentials of a composite diamond/silicon microcantilever for parametric generation of AFCs in ambient air.

View Article and Find Full Text PDF

Background: Bleeding and thrombotic occlusion are complications of Central venous catheters. When selecting a catheter lock solution, factors such as bleeding, thrombotic occlusion, infection, and cost-effectiveness must be considered.

Methods: The study included 35 patients who used heparin as a locking solution and 35 patients who used 0.

View Article and Find Full Text PDF

Background: Fragile X syndrome (FXS) is a leading known genetic cause of intellectual disability and autism spectrum disorders (ASD)-associated behaviors. A consistent and debilitating phenotype of FXS is auditory hypersensitivity that may lead to delayed language and high anxiety. Consistent with findings in FXS human studies, the mouse model of FXS, the Fmr1 knock out (KO) mouse, shows auditory hypersensitivity and temporal processing deficits.

View Article and Find Full Text PDF

An ultra-narrow-linewidth laser is a core device in fields such as optical atomic clocks, quantum communications, and microwave photonic oscillators. This paper reports an ultra-narrow-linewidth self-injection locked semiconductor laser, which is realized through optical feedback from a high-Q (258 million) Fabry-Perot (FP) cavity constructed with three mirrors, generating an output power of 12 mW. Employing a delay self-heterodyne method based on a signal source analyzer, the phase noise of the laser is -129 dBc/Hz at 100 kHz offset frequency, with an intrinsic linewidth of 3 mHz.

View Article and Find Full Text PDF

Objective: A Leonis Mova (LM; SB Kawasumi, Kanagawa, Japan), one of the steerable microcatheters, has a remote-controlled flexible catheter tip manipulated with a dial in the hand grip, which enables operators to overcome complicated branching in endovascular surgeries. We report a case of a pituitary tumor in which the LM worked effectively as a distal access catheter (DAC) in tumor embolization.

Case Presentation: A female patient in her 70s complained of bitemporal hemianopsia, and an MRI revealed a pituitary tumor that appeared hypervascular.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!