We report the design, development, and implementation of an improved instrumentation approach for frequency-domain fluorescence lifetime (FDFL) optrodic sensing without a concurrent reference LED. FDFL traditionally uses a reference LED, at approximately the same wavelength as the sensor fluorophore emission, to measure phase shifts associated with changes in the fluorescence lifetime of fluorophore. For this work we used an oxygen optrode to design, develop, and test the reference-LED-free FDFL approach. Electronics and optics were optimized, and key system parameters, such as inherent system phase shifts, were determined to insure best performance. In our tests with the oxygen optrode, we observed that several key performance characteristics were improved by the implementation of the reference-LED-free instrumentation platform. This system can potentially be adapted to other analyte-selective fluorophores, which will enable scientists and researchers to expand the application of optrodic sensors as basic research tools in biology, medicine, and agriculture.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.48.005528DOI Listing

Publication Analysis

Top Keywords

fluorescence lifetime
12
frequency-domain fluorescence
8
concurrent reference
8
reference led
8
phase shifts
8
oxygen optrode
8
lifetime optrode
4
system
4
optrode system
4
system design
4

Similar Publications

Herein, a water-soluble, ultrabright, near-infrared (NIR) fluorescent, mechanically interlocked molecules (MIMs)-peptide bioconjugate is designed with dual targeting capabilities. Cancer cell surface overexpressed αβ integrin targeting two RGDS tetrapeptide residues is tethered at the macrocycle of MIMs-peptide bioconjugate via Cu(I)-catalyzed click chemistry on the Wang resin, and mitochondria targeting lipophilic cationic TPP functionality is conjugated at the axle dye. Living carcinoma cell selective active targeting, subsequently cell penetration, mitochondrial imaging, including the ultrastructure of cristae, and real-time tracking of malignant mitochondria by MIMs-peptide bioconjugate (RGDS)-Mito-MIMs-TPP are established by stimulated emission depletion (STED) super-resolved fluorescence microscopy.

View Article and Find Full Text PDF

Preimplantation genetic diagnosis (PGD) is provided by majority of reproductive clinics in the United States (US), and PGD is used in many in vitro fertilization (IVF) procedures every year. PGD is extensively used to screen for certain genetic abnormalities and aneuploidy in individuals undergoing IVF. Genetic disorders are very prevalent in Saudi Arabia.

View Article and Find Full Text PDF

Background: Up to 23% of breast cancer patients recurred within a decade after trastuzumab treatment. Conversely, one trial found that patients with low HER2 expression and metastatic breast cancer had a positive response to trastuzumab-deruxtecan (T-Dxd). This indicates that relying solely on HER2 as a single diagnostic marker to predict the efficacy of anti-HER2 drugs is insufficient.

View Article and Find Full Text PDF

Inward rectifying potassium (Kir) channels play a critical role in maintaining the resting membrane potential and cellular homeostasis. The high-resolution crystal structure of homotetrameric KirBac1.1 in detergent micelles provides a snapshot of the closed state.

View Article and Find Full Text PDF

Pendant organic chromophores have been used to improve the photocatalytic performance of many metal-based photosensitizers, particularly in first-row metals, by increasing π conjugation in ligands and lowering the energy of the photoactive absorption band. Using a combination of spectroscopic studies and computational modeling, we rationalize the excited state dynamics of a Co(III) complex containing pendant pyrene moieties, , where = 1,1'-(4-(pyren-1-yl)pyridine-2,6-diyl)bis(3-methyl-1-imidazol-3-ium). displays higher visible absorptivity, and blue luminescence from pyrene singlet excited states compared with [ = 1,1'-(pyridine-2,6-diyl)bis(3-methyl-1-imidazol-3-ium)] in which the pyrene moiety is absent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!