The main problems in intra-medullary nailing of femoral shaft-fractures are leg-length discrepancies and rotational differences with an incidence of 2-18% and 20-40% respectively. These may lead to severe postoperative sequelae such as additional correctional operations and difficult rehabilitation. Insufficient visualization can be considered the main reason for these complications. Finally, retention of the fragments in the correct alignment before nail insertion is difficult. To overcome these problems we established a robotic telemanipulator system to support the reduction process. It was evaluated in 30 fractures of embalmed human femora. Specially programmed software used an image-dataset which was acquired by an isocentric 3D fluoroscope. For visualization, a surface projection was generated. Localization and tracking of the fragments and the robot-arm as well as accuracy measurement was performed by using an optical navigation system. Manipulation was controlled via a force-feedback joystick. This way, collisions of the fragments were transmitted back to the surgeon. At the end of the reduction the robot could rigidly retain the fragments' position.

Download full-text PDF

Source
http://dx.doi.org/10.3233/THC-2009-0544DOI Listing

Publication Analysis

Top Keywords

visualized robot
4
robot assisted
4
assisted reduction
4
reduction femoral
4
femoral shaft
4
shaft fractures
4
fractures evaluation
4
evaluation exposed
4
exposed cadaveric
4
cadaveric bones
4

Similar Publications

Nasopharyngeal stenosis is a challenging condition characterized by a narrowed nasopharynx, leading to nasal congestion, impaired breathing, and recurrent sinus issues. In this report, we present a unique surgical approach that combines the use of both the Da Vinci Xi robot and a 70-degree nasal endoscope in a patient with a type II stenosis of the nasopharynx. The benefits of improved visualization, maneuverability, and precision of this novel combined approach are highlighted.

View Article and Find Full Text PDF

Smart cities deploy various sensors such as microphones and RGB cameras to collect data to improve the safety and comfort of the citizens. As data annotation is expensive, self-supervised methods such as contrastive learning are used to learn audio-visual representations for downstream tasks. Focusing on surveillance data, we investigate two common limitations of audio-visual contrastive learning: false negatives and the minimal sufficient information bottleneck.

View Article and Find Full Text PDF

Metabolic Fingerprint of Dual Body Fluids Deciphers Diabetic Retinopathy.

Small

January 2025

Department of Ophthalmology, National Clinical Research Center for Eye Diseases, Shanghai Gene Therapy Center, Shanghai Key Laboratory of Ocular Fundus Disease, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200040, P. R. China.

Diabetic retinopathy (DR) is a microvascular complication of diabetes, affecting 34.6% of diabetes patients worldwide. Early detection and timely treatment can effectively improve the prognosis of DR.

View Article and Find Full Text PDF

Objective: To evaluate in a systematic review the outcomes, benefits, and limitations of robot-assisted surgeries for paediatric neurogenic lower urinary tract dysfunction (LUTD), as robot-assisted techniques have emerged as a potential alternative, offering enhanced precision, dexterity, and visualisation.

Methods: This review was registered in the International Prospective Register of Systematic Reviews (PROSPERO identifier CRD42023464849) and adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We included studies of paediatric patients (aged <18 years) with neurogenic LUTD undergoing robot-assisted continence surgery, assessing safety and efficacy.

View Article and Find Full Text PDF

Background: Histotripsy is a non-invasive, non-ionizing, non-thermal focused ultrasound technique. High amplitude short acoustic pulses converge to create high negative pressures that cavitate endogenous gas into a bubble cloud leading to mechanical tissue destruction. In the United States, histotripsy is approved to treat liver tumors under diagnostic ultrasound guidance but in initial clinical cases, some areas of the liver have not been treated due to bone or gas obstructing the acoustic window for targeting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!