Venous occlusion plethysmography (VOP) is a valid non-invasive method to assess peripheral blood flow (BF) in humans. Our aim was to determine intra- and inter-tester reproducibility of BF analysis using a traditional manual method and a novel system, based on a semi-automatic approach. Ten healthy subjects and ten subjects with chronic heart failure (CHF) were evaluated. Blood flow was measured on the forearm at baseline and after 5 min of circulatory occlusion (reactive hyperemia (RH)). Two testers independently and blindly analyzed each VOP recording. Both methods were highly reproducible intra- and inter-testers. In addition, there was a high association between the methods, since the intraclass correlation coefficients (ICCs) for healthy subjects were 0.99, 0.99 and 0.99, and the coefficients of variation (CVs) were 1.8, 2.4 and 1.6% for baseline, RH peak and RH area under the curve, respectively. For CHF subjects, the ICCs were 0.99, 0.98 and 0.99, and the CVs were 2.9, 3.6 and 2.0%. In addition, the time spent on the semi-automatic analyses was shorter (p < 0.05). In conclusion, both methods demonstrated high intra- and inter-tester reproducibility for baseline and RH BF analysis. However, since the semi-automatic method was faster to generate the results, the present study supports its usage for the analysis of BF measured by VOP.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0967-3334/30/11/010DOI Listing

Publication Analysis

Top Keywords

intra- inter-tester
12
inter-tester reproducibility
12
blood flow
12
venous occlusion
8
occlusion plethysmography
8
semi-automatic method
8
healthy subjects
8
099 099
8
099
5
intra-
4

Similar Publications

The PULSE workload monitor (PULSE) is a commercially available, wearable device that assesses upper extremity kinematics and kinetics during overhand pitching with three metrics to improve pitching performance. The purpose of this study was to determine the inter-tester and intra-tester reliability of the PULSE metrics when applied by a lay consumer versus trained researcher. A total of 14 healthy, adult male (age: 44.

View Article and Find Full Text PDF

Ultrasound evaluation of deep fascia thickness: Reliability and association with clinically evaluated changes.

J Bodyw Mov Ther

October 2024

Department of Physical Therapy, Recanati School for Community Health Professions, Faculty of Health Sciences at Ben-Gurion University of the Negev, Beer-Sheva, Israel. Electronic address:

Background: There is growing evidence of fascial involvement in musculoskeletal pathologies; thus, measuring the fascia's properties is clinically essential.

Objectives: 1) to evaluate intra- and inter-tester reliability of sonographic measurements of deep fascia thickness in healthy individuals; 2) to assess whether fascial thickness in areas of fascial movement restriction (fascial densification in Stecco's Fascial Manipulation method), differs from contralateral areas with normal fascia.

Methods: Part 1 (reliability study): Fascial thickness was sonographically measured in 10 sites (5 on each side), twice by a single examiner to assess intra-rater reliability and once by a second examiner to evaluate inter-rater reliability.

View Article and Find Full Text PDF

An assessment of protocol reliability is an essential step prior to human subject testing for injury prevention. The purpose of this study was to examine the inter-rater and intra-rater reliability of a portable cervical range of motion and isometric strength protocol designed for special forces combat soldiers who are at risk for cervical spine pain and injury due to exposure to head-supported mass. Eight individuals were tested three times to assess reliability, the standard error of the measurement (SEM), and the minimal detectable change across six range of motion measures and six strength measures of the cervical spine.

View Article and Find Full Text PDF

Knee injuries are common among all age groups, and clinical knee examination is essential for the prognosis, follow-up, and rehabilitation process. The Lachmeter is a newly developed digitized modification of the Rolimeter, making it easier and faster for the test personnel to read the test result. In the present study, we aimed to evaluate the intra-tester and inter-tester reliability of the Lachmeter when testing healthy and traumatic knees.

View Article and Find Full Text PDF

Background: The current standard to evaluate the presence of somatosensory dysfunctions is quantitative sensory testing, but its clinical utility remains limited. Low-cost and time-efficient clinical sensory testing (CST) batteries have thus been developed. Recent studies show moderate to substantial reliability in populations with neuropathic pain.

View Article and Find Full Text PDF