Objective: To demonstrate how radial and ulnar deviation of the wrist can affect the visualization of the intrinsic intercarpal ligaments using magnetic resonance (MR) imaging, MR arthrography and gross anatomic inspection in cadavers.
Materials And Methods: The detectability of the intrinsic intercarpal ligaments of ten fresh human wrists was analyzed in coronal, axial and sagittal images in the neutral position and in radial and ulnar deviation with MR imaging and MR arthrography. The findings were then correlated with gross anatomic inspection. Additionally, quantitative measurements including the radiocarpal distances and capitate angles were performed.
Results: Differences were noted in the visual conspicuity of only the intercarpal ligaments of the proximal carpal row with different techniques and wrist positions. The average width of the radiocarpal joint was 0.62 mm, 1.55 mm and 2.0 mm (radial side) and 3.78 mm, 2.25 mm and 1.16 mm (ulnar side) in radial deviation, neutral position, and ulnar deviation of the wrist, respectively. Statistically, these maneuvers produced significant opening in the ulnar side during radial deviation (Student's t-test; P = 0.0005) and in the radial side in ulnar deviation (P = 0.007).
Conclusion: Significant differences in the width of the radiocarpal joint were observed during radial and ulnar deviation of the wrist, influencing the visualization of the intrinsic ligaments, mainly the scapholunate and lunotriquetral ligaments. The use of MR arthrography with radial and/or ulnar deviation has the potential to improve diagnosis in clinical cases in which injury to one or both of these ligaments is suggested.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2895879 | PMC |
http://dx.doi.org/10.1007/s00256-009-0796-5 | DOI Listing |
Sensors (Basel)
January 2025
Division of Robotics, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Orthopaedic Surgery, School of Medicine, International University of Health and Welfare (IUHW), Narita Hospital, 852 Hatakeda, Narita 286-8520, Japan.
Rheumatoid arthritis (RA) causes persistent synovitis and arthritis, resulting in joint deformity and destruction throughout the body. As RA medications have evolved over the past 30 years, the surgical indications and techniques for RA joint deformities have changed. The aim of this review article is to summarize the recent trend of surgery for rheumatoid hand/finger deformities in previous reports and to present our recent surgical methods and outcomes for these deformities.
View Article and Find Full Text PDFChildren (Basel)
January 2025
University Hospital of Lausanne, 1011 Lausanne, Switzerland.
Objectives: The scaphoid fat pad stripe (SFS) is a radiological sign first described in 1975 as a line of relative lucency lying parallel to the lateral border of the scaphoid, with slight convexity toward it, and it is optimally demonstrated on postero-anterior and oblique views with ulnar deviation of the carpus. The obliteration or displacement of this line is commonly present in acute fractures of the scaphoid, radial styloid process, and proximal first metacarpus. The aim of this observational study is to investigate the supportive value of the fat stripe sign (SFS) in the diagnosis of scaphoid fractures in the pediatric population.
View Article and Find Full Text PDFBiomimetics (Basel)
January 2025
Faculty of Engineering, Tokyo Polytechnic University, 1583 Iiyama, Atsugi 243-0297, Kanagawa, Japan.
Wrist movements play a crucial role in upper-limb motor tasks. As prosthetic and robotic hand technologies have evolved, increasing attention has been focused on replicating the anatomy and functionality of the wrist. Closely imitating the biomechanics and movement mechanisms of human limbs is expected to enhance the overall performance of bionic robotic hands.
View Article and Find Full Text PDFZhongguo Gu Shang
January 2025
Unit 66322 of the People's Liberation Army, Beijing 100000, China.
Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!