A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Serum levels of large tenascin-C variants, matrix metalloproteinase-9, and tissue inhibitors of matrix metalloproteinases in concentric versus eccentric left ventricular hypertrophy. | LitMetric

Aims: Chronic hypertension may cause left ventricular hypertrophy (LVH). The role of matrix metalloproteinases (MMPs), tissue inhibitors of matrix metalloproteinases (TIMPs), and tenascin-C (Tn-C) splice variants in concentric vs. eccentric left ventricular remodelling has not been investigated.

Methods And Results: Serum levels of B or C domain containing Tn-C, MMP-9, TIMP-1, -2, and -4 were determined in concentric (left ventricular posterior wall thickness >13 mm and intraventricular septum >13 mm, n = 61) and eccentric (end-diastolic left ventricular diameter >55 mm or end-systolic left ventricular diameter >40 mm, n = 34) LVH by enzyme-linked immunoassays. Levels of B domain containing Tn-C were higher in patients with LVH than in normal volunteers (P = 0.020) and higher in eccentric LVH (EH) compared with concentric LVH (CH) (P = 0.003). A cut-off value of 900 ng/mL might discriminate between these different forms of LVH. Matrix metalloproteinase-9 was higher in patients with LVH than in normal volunteers (P = 0.042), and levels were decreased in EH compared with CH (P = 0.028). Patients with LVH had higher levels of TIMP-1 (P = 0.059), TIMP-2 (P = 0.043), and TIMP-4 (P = 0.163) than normal volunteers, but there were no differences between the LVH groups.

Conclusion: Our data suggest that myocardial remodelling in LVH is associated with changes in serum levels of MMP-9, TIMP-1, -2, -4, and Tn-C splice variants. In addition, B domain containing Tn-C discriminated EH from CH and might be suggested as a potential diagnostic marker.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurjhf/hfp128DOI Listing

Publication Analysis

Top Keywords

left ventricular
24
serum levels
12
matrix metalloproteinases
12
domain tn-c
12
patients lvh
12
normal volunteers
12
lvh
10
matrix metalloproteinase-9
8
tissue inhibitors
8
inhibitors matrix
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!