A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of external noise on detection of intensity increments. | LitMetric

Effects of external noise on detection of intensity increments.

J Acoust Soc Am

Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA.

Published: October 2009

The detection of an intensity increment in a longer duration sinusoid or pedestal is often used as a measure of intensity resolution, but the decision processes underlying this measure are poorly understood. Thresholds were obtained for detection of an increment in a 370-ms, 4-kHz pedestal in quiet or in noise to determine the relative contributions of background noise level and pedestal level, the effect of increment duration, and the effect of different noise spectra. Increment detection thresholds expressed in units of DeltaL[10 log(1+DeltaI/I)] decreased as pedestal levels increased. At low pedestal levels, increment detection was limited by the masking effect of the noise and was similar across noise conditions for pedestals of equal sensation level. At high pedestal levels, the noise had no effect and increment detection was determined by the pedestal level in dB SPL (sound pressure level). Increment detection improved with increasing increment duration and was altered less by a noise band above the pedestal/increment frequency than by a broadband noise that produced equal masking at the pedestal/increment frequency. The quadratic-compression model described by Neely and Jesteadt [(2005). Acta Acust. Acust. 91, 980-991] provided a better approximation to the data than a model based on excitation patterns.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2771056PMC
http://dx.doi.org/10.1121/1.3203994DOI Listing

Publication Analysis

Top Keywords

increment detection
16
pedestal levels
12
noise
9
detection intensity
8
increment
8
pedestal level
8
level increment
8
increment duration
8
pedestal/increment frequency
8
detection
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!