Introduction: Most published data on relapse in open bite maxillo-mandibular deformities give raw results but do not suggest any specific therapy. Indeed, their authors compare the various osteotomy techniques but without identifying risk factors for relapse (dysfunctional or architectural). We studied the predictive value of occlusal plane tilting, in the long-term relapse of open bite maxillo-mandibular deformity.
Material And Method: Fifty patients were included between 1996 and 2007. For each patient, Delaire cephalometric analysis was performed on preoperative, immediate and late postoperative teleradiographs. Immediate real postoperative occlusal plane tilting was analyzed and compared with "ideal" theoretical occlusal plane tilting (calculated with Delaires' analysis). The patients were classified in two groups: one with slight discrepancy between these two planes (+/-3.75 degrees) and one with large discrepancies between these two planes (greater than 3.75 degrees or lesser than 3.75 degrees).
Results: Postoperative relapse was seven times more frequent when the postoperative plane tilting was superior to +/-3.75 degrees in reference to the ideal plane.
Discussion: Postoperative occlusal plane tilting is a predictive factor of postoperative open bite relapse.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.stomax.2009.09.002 | DOI Listing |
Nano Lett
January 2025
Department of Materials Science and Engineering, Cornell University, Ithaca, New York 14853, United States.
Controlling the Mott transition through strain engineering is crucial for advancing the development of memristive and neuromorphic computing devices. Yet, Mott insulators are heterogeneous due to intrinsic phase boundaries and extrinsic defects, posing significant challenges to fully understanding the impact of microscopic distortions on the local Mott transition. Here, using a synchrotron-based scanning X-ray nanoprobe, we studied the real-space structural heterogeneity during the structural phase transition in a VO thin film.
View Article and Find Full Text PDFJ Adv Prosthodont
December 2024
Department of Prosthodontics, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
Under-occlusion ('infraocclusion' as defined in the natural teeth) after implant restoration in the posterior area is commonly encountered in clinical practice; however, it has rarely been reported. Most importantly, the under-occlusion change mechanism remains unknown. The purpose of this case report was to analyze how the dentition of both arches changed in a patient, including teeth tilting, elongation and occlusal plane change with under-occlusion of the posterior implant restoration after long-term function.
View Article and Find Full Text PDFACS Mater Au
January 2025
Beijing National Laboratory for Molecular Science, State Key Laboratory of Rare Earth Materials Chemistry and Applications, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China.
Two-dimensional lead iodide perovskites have attracted significant attention for their potential applications in optoelectronic and photonic devices due to their tunable excitonic properties. The choice of organic spacer cations significantly influences the light emission and exciton transport properties of these materials, which are vital for their device performance. In this Perspective, we discuss the impact of spacer cations on lattice dynamics and exciton-phonon coupling, focusing on three representative 2D lead iodide perovskites that exhibit distinct types of structural distortions.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Department of Marine Design Convergence Engineering, Pukyong National University, 45 Yongso-ro, Nam-gu, Busan 48513, Republic of Korea.
Controlling microstructure and texture development is a key approach to improving the formability of magnesium alloys. In this study, the effects of the strain rate and initial texture on the texture evolution of magnesium alloys during high-temperature processing are investigated. The plane strain compression of three types of AZ80 magnesium alloys with different initial textures was assessed at 723 K and a train rate of 0.
View Article and Find Full Text PDFbioRxiv
December 2024
Lyda Hill Department of Bioinformatics, UT Southwestern Medical Center, Dallas, TX 75390, USA.
Oblique plane microcopy (OPM), a variant of light-sheet fluorescence microscopy (LSFM), enables rapid volumetric imaging without mechanically scanning the sample or an objective. In an OPM, the sample space is mapped to a distortion free image space via remote focusing, and the oblique light-sheet plane is mapped via a tilted tertiary imaging system onto a camera. As a result, the 3D point-spread function and optical transfer function are tilted to the optical axis of the tertiary imaging system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!