Purpose: To determine the feasibility of detecting thrombi using a fibrin-specific gadolinium-based magnetic resonance imaging contrast agent, EP-2104R.

Methods: Subjects with confirmed thrombus in the venous system (n = 14), or in the heart, or arterial system (n = 38) were enrolled. Patients were imaged before and at various times following a 4 mumol/kg intravenous bolus injection of EP-2104R: <1 hour (N = 16), 2 to 6 hours (N = 36), and/or 20 to 36 hours (N = 33). Images were assessed by investigators at each site and by a single reader not affiliated with the sites to determine whether thrombi were visible, not visible, or further enhanced with EP-2104R. A subset of data was analyzed quantitatively by measuring a signal intensity relative to background tissue.

Results: Overall, 29 thrombi were visible before contrast administration, 3 of 14 in the venous system, and 26 of 38 in the arteries and heart. Thrombi generally enhanced in signal after EP-2104R injection, and an additional 7 were visualized. After contrast, 4 of 14 thrombi were visible in the venous system, and 32 of 38 in the arteries and heart. Thrombi were more conspicuous when imaged at 2 to 6 hours post EP-2104R compared with within 1 hour, because of lower blood background. Quantitatively, the post: pre signal intensity ratio was 1.90 at 2 to 6 hours post injection (standard deviation = 1.08, N = 20, P < 0.001); and 2.04 (standard deviation = 1.29, N = 19, P < 0.0025) for the 20 to 36 hours time point. There were no serious adverse events considered related to study drug.

Conclusion: EP-2104R enhanced magnetic resonance imaging detects thrombi not readily visible in precontrast screening and gives additional enhancement of thrombi that are visible in precontrast imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0b013e3181b092a7DOI Listing

Publication Analysis

Top Keywords

fibrin-specific gadolinium-based
8
contrast agent
8
thrombus imaging
4
imaging fibrin-specific
4
gadolinium-based contrast
4
agent ep-2104r
4
ep-2104r phase
4
phase clinical
4
clinical study
4
study feasibility
4

Similar Publications

Fibrotic lung disease, most notably idiopathic pulmonary fibrosis (IPF), is thought to result from aberrant wound-healing responses to repetitive lung injury. Increased vascular permeability is a cardinal response to tissue injury, but whether it is mechanistically linked to lung fibrosis is unknown. We previously described a model in which exaggeration of vascular leak after lung injury shifts the outcome of wound-healing responses from normal repair to pathological fibrosis.

View Article and Find Full Text PDF

Purpose: To determine the feasibility of detecting thrombi using a fibrin-specific gadolinium-based magnetic resonance imaging contrast agent, EP-2104R.

Methods: Subjects with confirmed thrombus in the venous system (n = 14), or in the heart, or arterial system (n = 38) were enrolled. Patients were imaged before and at various times following a 4 mumol/kg intravenous bolus injection of EP-2104R: <1 hour (N = 16), 2 to 6 hours (N = 36), and/or 20 to 36 hours (N = 33).

View Article and Find Full Text PDF

Thrombus (blood clot) is implicated in a number of life threatening diseases, e.g., heart attack, stroke, pulmonary embolism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!