Background: Left ventricular (LV) apical rotation and twist can be estimated noninvasively by speckle-tracking echocardiography (STE). In this study, we tested whether apical rotation is an accurate index of LV contractility.

Methods And Results: We measured LV basal and apical rotation by STE in 11 open-chest anesthetized mongrel dogs under 8 different inotropic stages before and after ligation of either left anterior descending (n=6) or circumflex coronary artery (n=5). We measured LV pressure simultaneously with a high-fidelity pressure catheter and calculated LV ejection fraction (EF) with the biplane Simpson method and 2D echocardiography. Maximal positive dP/dt (dP/dt(max)) was used as the gold standard measurement of LV contractility. We compared LV twist and apical rotation and EF against dP/dt(max) by linear mixed model. LV apical rotation and twist showed dose-dependent increases and decreases after dobutamine and esmolol infusion, respectively. However, basal rotation did not change significantly during different inotropic conditions. There was a stronger association between dP/dt(max) and LV twist (R(2)=0.747, P<0.001) and apical rotation (R(2)=0.726, P<0.001) than between dP/dt(max) and EF (R(2)=0.408, P<0.001), and this trend was more apparent with coronary ligation irrespective of the ligation site. There was also a high association between dP/dt(max) and apical rotation alone, both with (R(2)=0.805, P<0.001) and without (R(2)=0.748, P<0.001) coronary ligation. Apical rotation alone showed comparable accuracy to LV twist. Apical rotational velocity also showed a high association with dP/dt(max) (R(2)=0.669, P<0.001) and LV twist (R(2)=0.892, P<0.001).

Conclusions: Apical rotation assessed by STE is an effective noninvasive index of global LV contractility and is more closely related to dP/dt(max) than LV EF.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.108.794719DOI Listing

Publication Analysis

Top Keywords

apical rotation
24
speckle-tracking echocardiography
8
left ventricular
8
rotation twist
8
apical
6
rotation
6
rotation assessed
4
assessed speckle-tracking
4
echocardiography global
4
global left
4

Similar Publications

Study Design: A retrospective comparative study.

Purpose: To validate the hypothesis that a combination of multilevel Ponte osteotomy (PO) with intraoperative traction (IOT) results in a better correction than IOT alone in high-magnitude curves in adolescent idiopathic scoliosis (AIS) and does not possess an attributable risk of neurological injury.

Overview Of Literature: On a comprehensive review of the literature, the choice of technique adopted for curves between 65° and 100° remains controversial with no major consensus favoring one technique over the other.

View Article and Find Full Text PDF

(1) Background: External force orthopedics and the strengthening of paraspinal muscles through exercise are common orthopedic methods for adolescent scoliosis, yet the synergetic mechanism of the two in orthopedic correction remains unclear. (2) Methods: A three-dimensional finite element model of the scoliotic spine was established to accurately simulate the mechanical properties of tissues such as the spine, intervertebral discs, and ribs. By applying external forces in different directions to the scoliosis model, the orthopedic effects of these forces on scoliosis were analyzed.

View Article and Find Full Text PDF

: Apical extrusion of debris can affect the success of endodontic treatments, and the specific performance of certain retreatment systems has not been studied yet. Therefore, the aim of this in vitro study was to quantitatively assess the amount of apically extruded debris produced during retreatment procedures using three rotary NiTi retreatment systems in mature non-resorbed straight roots. : Thirty extracted permanent human teeth with single straight roots were selected.

View Article and Find Full Text PDF

While the basal region of the left ventricle (LV) rotates in a clockwise (cw) direction, the apical regions of the LV rotate in a counterclockwise (ccw) direction in healthy circumstances. Although LV rotational mechanics help optimize LV ejection, in some cases, LV twist is missing. This clinical situation, when the LV base and the apex rotate in the same cw or ccw direction, is called LV 'rigid body rotation' (LV-RBR).

View Article and Find Full Text PDF

The growing demand for artificial intelligence (AI) in healthcare is driven by the need for more robust and automated diagnostic systems. These methods not only provide accurate diagnoses but also promise to enhance operational efficiency and optimize resource utilization in clinical workflows. In the field of dental lesion detection, the application of deep learning models to various imaging techniques has gained significant prominence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!