A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Concurrent assessment of epicardial coronary artery stenosis and microvascular dysfunction using diagnostic endpoints derived from fundamental fluid dynamics principles. | LitMetric

Background: Simultaneously measured pressure and flow distal to coronary stenoses can be combined, in conjunction with anatomical measurements, to assess the status of both the epicardial and microvascular circulations.

Methods And Results: Assessments of coronary hemodynamics were performed using fundamental fluid dynamics principles. We hypothesized that the pressure-drop coefficient (CDPe; trans-stenotic pressure drop divided by the dynamic pressure in the distal vessel) correlates linearly with epicardial and microcirculatory resistances concurrently. In 14 pigs, simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire in the setting of both normal and disrupted microcirculation, with the presence of epicardial coronary lesions of lt; 50% area stenosis (AS) and > 50% AS. The CDPe progressively increased from lesions of < 50% AS to > 50% AS and had a higher resolving power (45 +/- 22 to 193 +/- 140 in normal microcirculation; 248 +/- 137 to 351 +/- 140 in disrupted microcirculation) as compared to fractional flow reserve (FFR) and coronary flow reserve (CFR). Strong multiple linear correlation was observed for CDPe with combined FFR and CFR (r = 0.72; p < 0.0001). Further, the ratio of maximum pressure drop coefficient evaluated at the site of stenosis and its theoretical limiting value of minimum cross-sectional area was also able to distinguish different combinations of coronary artery diseases.

Conclusions: The CDPe can be readily obtained during routine pressure and flow measurements during cardiac catheterization. It is a promising clinical diagnostic parameter that can independently assess the severity of epicardial stenosis and microvascular impairment.

Download full-text PDF

Source

Publication Analysis

Top Keywords

pressure flow
12
epicardial coronary
8
coronary artery
8
stenosis microvascular
8
fundamental fluid
8
fluid dynamics
8
dynamics principles
8
distal coronary
8
pressure drop
8
disrupted microcirculation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!