The aim of this study was to assess urinary bladder histopathology induced by the sling materials tension-free vaginal tape (TVT), vypro mesh, and intravaginal slingplasty (IVS). Thirty rats were studied: sham-operated controls, TVT, vypro, and IVS groups. After laparotomy, a 0.5- "e 1-cm piece of mesh was implanted on the anterior bladder wall. The bladder was examined histopathologically after 12 weeks. Inflammation, foreign-body reaction, subserosal fibrosis, necrosis, and collagen deposition were graded. The Kruskal-Wallis and posthoc Dunn tests were used. The sham-operated rats showed no tissue reactions. The TVT, vypro, and IVS groups showed increased inflammation (p = 0.006, p = 0.031, p = 0.001), subserosal fibrosis (p = 0.0001), foreign-body reaction (p = 0.0001), and collagen deposition (p = 0.0001) as compared to sham. Inflammation was more intense in the IVS group as compared to the TVT and vypro groups (p = 0.041, p = 0.028). The bladder presented more increased inflammatory response to IVS than the other meshs. This may play a role in the ultimate outcomes or complications from slings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5823133PMC
http://dx.doi.org/10.1100/tsw.2009.120DOI Listing

Publication Analysis

Top Keywords

tvt vypro
16
urinary bladder
8
vypro ivs
8
ivs groups
8
foreign-body reaction
8
subserosal fibrosis
8
collagen deposition
8
bladder
5
ivs
5
tissue reaction
4

Similar Publications

Objective: Pelvic organ prolapse affect 50% of parous women over 50 years of age. The lifetime risk of undergoing a single operation for prolapse or incontinence by age 80 is 11.1%.

View Article and Find Full Text PDF

The aim of this study was to assess urinary bladder histopathology induced by the sling materials tension-free vaginal tape (TVT), vypro mesh, and intravaginal slingplasty (IVS). Thirty rats were studied: sham-operated controls, TVT, vypro, and IVS groups. After laparotomy, a 0.

View Article and Find Full Text PDF

Biocompatible properties of surgical mesh using an animal model.

Aust N Z J Obstet Gynaecol

February 2006

Urogynaecology Unit, Gold Coast Hospital, Southport, Queensland. Australia.

Aim: To study the biocompatibility of surgical meshes for use in pelvic reconstructive surgery using an animal model.

Methods: Eight different types of mesh: Atrium, Dexon, Gynemesh, IVS tape, Prolene, SPARC tape, TVT tape and Vypro II, were implanted into the abdominal walls of rats for 3 months' duration. Explanted meshes were assessed, using light microscopy, for parameters of rejection and incorporation.