Rationale: Sirolimus-eluting coronary stents (SESs) and paclitaxel-eluting coronary stents (PESs) are used to reduce restenosis but have different sites of action. The molecular targets of sirolimus overlap with those of the peroxisome proliferator-activated receptor (PPAR)gamma agonist rosiglitazone (RSG) but the consequence of this interaction on endothelialization is unknown.

Objective: Using the New Zealand white rabbit iliac model of stenting, we examined the effects of RSG on SESs, PESs, and bare metal stents endothelialization.

Methods And Results: Animals receiving SESs, PESs, or bare metal stents and either RSG (3 mg/kg per day) or placebo were euthanized at 28 days, and arteries were evaluated by scanning electron microscopy. Fourteen-day organ culture and Western blotting of iliac arteries and tissue culture experiments were conducted. Endothelialization was significantly reduced by RSG in SESs but not in PESs or bare metal stents. Organ culture revealed reduced vascular endothelial growth factor in SESs receiving RSG compared to RSG animals receiving bare metal stent or PESs. Quantitative polymerase chain reaction in human aortic endothelial cells (HAECs) revealed that sirolimus (but not paclitaxel) inhibited RSG-induced vascular endothelial growth factor transcription. Western blotting demonstrated that inhibition of molecular signaling in SES+RSG-treated arteries was similar to findings in HAECs treated with RSG and small interfering RNA to PPARgamma, suggesting that sirolimus inhibits PPARgamma. Transfection of HAECs with mTOR (mammalian target of rapamycin) short hairpin RNA and with Akt2 small interfering RNA significantly inhibited RSG-mediated transcriptional upregulation of heme oxygenase-1, a PPARgamma target gene. Chromatin immunoprecipitation assay demonstrated sirolimus interferes with binding of PPARgamma to its response elements in heme oxygenase-1 promoter.

Conclusions: mTOR/Akt2 is required for optimal PPARgamma activation. Patients who receive SESs during concomitant RSG treatment may be at risk for delayed stent healing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4492118PMC
http://dx.doi.org/10.1161/CIRCRESAHA.109.200519DOI Listing

Publication Analysis

Top Keywords

bare metal
20
sess pess
12
pess bare
12
metal stents
12
sirolimus paclitaxel
8
metal stent
8
ppargamma activation
8
coronary stents
8
rsg
8
rsg sess
8

Similar Publications

Coated metallic stents are the next generation of metallic stents with improved surface properties. To evaluate the degradation behavior of stents in vitro, different in vitro degradation models can be applied: (i) static immersion test: degradation under static fluid condition, (ii) fluid dynamic test: degradation under flowing fluid, and (iii) electrochemical corrosion test: degradation under the influence of electric potential. During these experimental procedures, stents interact with the simulated blood plasma, and degradation products are formed in the form of depositions on the stent surface, likewise in vivo experiments.

View Article and Find Full Text PDF

Dihydromyricetin (DMY), as the main active ingredient in , is a naturally occurring flavonoid that has attracted extensive attention for its multiple biological activities. For the quick and accurate measurement of DMY, a novel electrochemical sensor based on a glassy carbon electrode (GCE) modified with a cobalt metal-organic framework (Co-MOF) was proposed in this work. The Co-MOF was synthesized via a single-step hydrothermal process using Co(NO)·6HO.

View Article and Find Full Text PDF

Cellulase was effectively immobilized onto an epoxy-bound chitosan-modified zinc metal-organic framework (epoxy/ZIF-8/CS/cellulase) support, yielding a conjugation rate of 0.64 ± 0.02 mg/cm2 and retaining 80.

View Article and Find Full Text PDF

Untangling the role of single-atom substitution on the improvement of the hydrogen evolution reaction of YNS MXene in acidic media.

Phys Chem Chem Phys

January 2025

Departamento de Física Aplicada - Instituto de Ciencia de Materiales, Matter at High Pressure (MALTA) Consolider Team, Universidad de Valencia, Edificio de Investigación, C/Dr Moliner 50, Burjassot, 46100, Valencia, Spain.

The production of hydrogen (H) fuel through electrocatalysis is emerging as a sustainable alternative to conventional and environmentally harmful energy sources. However, the discovery of cost-effective and efficient materials for this purpose remains a significant challenge. In this study, we explore the potential of the transition-metal-substituted YNS MXene as a promising candidate for hydrogen production through the hydrogen evolution reaction (HER).

View Article and Find Full Text PDF

Arch Bare Metal Stent Grafting in Type I Aortic Dissections After Hemiarch Repair.

Ann Thorac Surg Short Rep

December 2024

Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.

Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!