A planar array infrared (PA-IR) spectrograph containing an attenuated total internal reflection (ATR) accessory has been constructed in order to permit rapid analysis of poorly transmitting materials. The technique has been optimized to allow molecular spectroscopic information to be collected in roughly 2 seconds with a corresponding peak-to-peak noise value as low as 2.14 x 10(-4) absorbance units. Additionally, up to 150 spectra could be extracted from sample sizes as large as 6 mm where each spatial element measured 40 x 200 microm at the sample position. An application study for this technique entailed developing an embedding method that allows cross-sectioned pharmaceutical tablets to be brought into intimate contact with the internal reflection element (IRE) of the accessory. A supplemental investigation involved calculating the yield strength of multiple IRE materials in order to determine the maximum amount of pressure that can be applied to a sample without damaging the IRE. Finally, feasibility was demonstrated for using the instrument/accessory as a means to rapidly authenticate suspected counterfeit pharmaceutical tablets.

Download full-text PDF

Source
http://dx.doi.org/10.1366/000370209789379321DOI Listing

Publication Analysis

Top Keywords

internal reflection
12
pharmaceutical tablets
12
attenuated total
8
total internal
8
planar array
8
array infrared
8
counterfeit pharmaceutical
8
rapid molecular
4
molecular imaging
4
imaging attenuated
4

Similar Publications

The motile parameters of kinesin superfamily proteins are fundamental to intracellular transport. Single-molecule motility assays using total internal reflection fluorescence (TIRF) microscopy are a gold standard technique for measuring the motile parameters of kinesin motors. With this technique, one can evaluate the velocity, run length, and binding frequency of kinesins on microtubules by directly observing their motility.

View Article and Find Full Text PDF

Organization Theory for Implementation Science (OTIS): reflections and recommendations.

Front Health Serv

December 2024

Department of Health Systems and Population Health, School of Public Health, University of Washington, Seattle, WA, United States.

Organizations exert influence on the implementation of evidence-based practices and other innovations that are independent of the influence of organizations' individual constituents. Despite their influence, nuanced explanations of organizations' influence remain limited in implementation science. Organization theories are uniquely suited to offer insights and explain organizational influences on implementation.

View Article and Find Full Text PDF

Introduction Multiple sclerosis (MS) afflicts over 2.8 million individuals worldwide and is a leading cause of neurological impairment in young adults. This study investigates the public interest in MS and its treatment options in the United States over the past decade, utilizing Google Trends data.

View Article and Find Full Text PDF

Satellite observations from the Clouds and the Earth's Radiant Energy System show that Earth's energy imbalance has doubled from 0.5 ± 0.2 Wm during the first 10 years of this century to 1.

View Article and Find Full Text PDF

Prognostic Implications of the Bethesda System in Fine-Needle Aspiration for Follicular Thyroid Carcinoma.

Arch Pathol Lab Med

December 2024

From the Department of Medicine, Thyroid Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea (SW Kim, JH Chung, TH Kim).

Context.—: Fine-needle aspiration is an effective tool for sampling thyroid nodules; its results are classified according to the Bethesda System for Reporting Thyroid Cytopathology (BSRTC), whose categories define malignancy risks.

Objective.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!