Background: We sought to assess predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in patients receiving primary prevention ICDs.

Methods: Four hundred twenty-one consecutive patients (ischemic and nonischemic) undergoing primary prevention ICD implantation were studied. Patients were grouped based on the presence/absence of appropriate ICD therapy. Summary data and stored electrograms from ICDs were reviewed to determine appropriateness of therapy. Predictors of therapy were assessed by both univariate and multivariate Cox regression analysis.

Results: Of 421 primary prevention patients undergoing ICD implantation, 79 (19%) had received appropriate ICD therapies. By univariate comparison, nonsustained ventricular tachycardia (NSVT), male sex, left ventricle diastolic diameter (LVDD), and hypertension were all significant predictors for ICD therapy over a mean follow-up time of 751 +/- 493 days (P
Conclusions: ICD-delivered therapy occurred in 19% of primary prevention patients with both ischemic and dilated cardiomyopathy and was predicted by NSVT and a lack of beta-blocker use.