Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Polyarylsulfone group is one of the most important polymeric materials used in the biomedical field, due to its excellent properties, such as good thermal, chemical, and mechanical stability. There are three important polyarylsulfone polymers, all of which have excellent electrical properties: polysulfone (PSu), polyarylsulfone (PAS) and polyarylethersulfone (PAES). All these polymers have excellent creep, radiation and high temperature resistance. In this study, we aimed to determine the effect of three sterilization processes (steam, ethylene oxide and gamma rays) on cytotoxicity of polyarylsulfone dialysis membranes. Ten long-term dialysis patients and ten age-matched healthy controls were enrolled in our study. We analysed (1) serum effect on cultured endothelial cell viability using MTT assay and (2) lipid peroxidation assessed by serum malondialdehyde (MDA) formation at the beginning (T0), the middle (T2) and the end (T4) of haemodialysis (HD) session. Our results clearly showed that steam-sterilized membranes improve endothelial cell viability when compared to ethylene oxide or gamma rays-sterilized ones. Moreover, there is a increased generation of MDA in patients sera during HD session. The serum MDA concentration was about 3, 6 and 10 times higher, respectively, for steam, ethylene oxide and gamma rays sterilization procedures when compared to the MDA amount in healthy subject sera. We concluded that using steam instead of ethylene oxide or gamma rays for sterilization may improve the biocompatibility of polyarylsulfone membranes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11255-009-9653-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!