Background And Objective: Animal studies using open surgical models indicate that collagen solder is capable of fixation of surgical meshes without interfering with tissue integration, increasing adhesions, or increasing inflammation intraperitoneally. This study describes development of instrumentation and techniques for laparoscopic herniorrhaphy using laser-assisted soldering technology.

Study Design And Methods: Anesthetized 20 kg to 25 kg female Yorkshire pigs underwent laparoscopy with a 3-trocar technique. Parietex TET, Parietex TEC, and Prolene mesh segments (5 x 5 cm) were embedded in 55% collagen solder. Segments were inserted by using a specially designed introducer and affixed to the peritoneum by using prototype laser devices (1.45 micro, 4.5 W continuous wave, 5-mm spot, 55 degrees C set temperature) and a custom laparoscopic handpiece (IPOM). Parietex PCO mesh was inserted and affixed using the Endo-hernia stapler (Control). Animals were recovered and underwent second-look laparoscopy at 6 weeks. Mesh sites were harvested after animals were euthanized.

Results: The mesh-solder constructs were easily inserted and affixed in an IPOM approach. Prolene mesh tended to curl at its edges as the solder was melted. Postoperative healing was similar to that in Control segments in all cases.

Discussion And Conclusion: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce the use of staples or other foreign bodies for laparoscopic mesh fixation, prevent tissue ischemia and possibly nerve entrapment, which result in severe postoperative pain and morbidity. Laser-assisted mesh fixation is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3015974PMC

Publication Analysis

Top Keywords

mesh fixation
12
laparoscopic mesh
8
tissue soldering
8
collagen solder
8
laparoscopic herniorrhaphy
8
prolene mesh
8
inserted affixed
8
mesh
6
laparoscopic
5
fixation
4

Similar Publications

Purpose: Forceful coughing is assumed to be an uncommon etiology for lateral abdominal wall hernias. The literature regarding this topic is very limited and there is a lack of consensus in management, both operative and non-operative. We aim to report our center's experience in repair of lateral abdominal wall hernias secondary to vigorous coughing.

View Article and Find Full Text PDF

Shape-memory materials are widely utilized in biomedical devices and tissue engineering, particularly for their ability to undergo predefined shape changes in response to external stimuli. In this study, a shape-transformable organohydrogel was developed by incorporating a gallium mesh into a polyacrylamide/alginate/glycerol matrix. The gallium mesh, which transitions between solid and liquid states at moderate temperatures (~29.

View Article and Find Full Text PDF

Conversion of 2-dimensional to 3-dimensional mesh for resource-limited centres in developing countries.

J Minim Access Surg

December 2024

Department of General Surgery, Shreeji Hospital, Bhilad-Valsad, Gujarat, India.

Background: In recent years, laparoscopic hernia repair, i.e. transabdominal pre-peritoneal and totally extraperitoneal repairs have been considered the method of choice, especially for recurrent hernias after open repair or bilateral inguinal hernias.

View Article and Find Full Text PDF

Introduction: In laparoscopic inguinal hernia repair (LIHR), fixation means for meshes (FMMs) are commonly used to reduce hernia recurrence risk. Their use may result in post-operative pain (PP) and may even increase surgical time (ST). Recently, self-gripping meshes (SGMs) have been developed, which leave aside fixation devices; they could potentially reduce PP and even decrease ST.

View Article and Find Full Text PDF

Objective: Aim: To evaluate the early postoperative results of surgical treatment of patients with inguinal hernias after laparoscopic transabdominal preperitoneal inguinal hernia repair (TAPP) using invasive and non-invasive methods of fixation of prosthetic material.

Patients And Methods: Materials and Methods: The study included 76 patients (average age 61,4±15,3 years; 69 [91 %] males, 7 [9 %] females) with primary uncomplicated unilateral inguinal hernias who underwent TAPP. Patients were divided into two groups: group 1 - 52 patients in whom the AbsorbaTack fixation device was used to secure the mesh; group 2 - 24 patients in whom the LiquiBand FIX8 cyanoacrylate adhesive was used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!