The National Radiation Standard Laboratory of the Institute of Nuclear Energy Research (INER) designed and constructed an improved Attix style free-air ionisation chamber (FAC) for low-energy X-ray measurements. Clinically, X rays in this energy range are used in mammography radiology. This chamber is also used to perform air-kerma measurements. The original Attix two-sectional design was redesigned by INER using the piston design. The correction factors were determined experimentally for volume estimation, ion recombination and air attenuation. The aperture transmission, wall transmission, electron loss and photon scatter correction factors were determined using Monte Carlo calculations. INER established the Bureau International des Poids et Mesures (BIPM) X-ray beam code and performed a comparison of secondary standard air-kerma calibration factors for 10-50 kV low- energy X rays to verify the experimental accuracy and measurement consistency of the improved chamber. The INER-NMIJ/National Institute of Advanced Industrial Science and Technology (AIST) experimental results comparison using a transfer chamber yielded a difference <1.0% at the 95% confidence level in calibration factors. The overall uncertainty for the X-ray measurement in terms of air kerma was <0.6% at the 95% confidence level. These results indicated that the improved FAC is capable of serving as a primary standard as well as a trace standard in low-energy X-ray calibration services in Taiwan and even forming a basis for the future mammography X-ray air-kerma primary standard.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncp184 | DOI Listing |
Radiat Prot Dosimetry
May 2023
Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary.
Varian Halcyon (HA) linear accelerators (LINAC) require kilovoltage cone-beam computed tomography (CT) acquisition for all patients before all treatment fractions. The aim of this study is to compare dose indices of various available protocols with different calculation and measurement methods. CT dose index (CTDI) in mGy is a measure of the radiation dose output of a CT scanner.
View Article and Find Full Text PDFSensors (Basel)
January 2023
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
Biomed Phys Eng Express
December 2021
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tukuba, Japan.
Accurate radiation dosimetry is required for radiation protection in various environments. Therefore, dosemeters and dose-rate meters must be calibrated in standard radiation fields. The National Metrology Institute of Japan (NMIJ) expands the energy range of x-ray reference field measurement up to 450 kV using a cylindrical graphite-walled cavity ionization chamber.
View Article and Find Full Text PDFRadiat Prot Dosimetry
November 2021
Division of Ionizing Radiation Metrology, National Institute of Metrology, No. 18, Bei San Huan Dong Lu, Chaoyang Dist., Beijing 100029, China.
Accurate dose measurement is very important for diagnosing X-ray equipment. These equipment should be traced directly or indirectly to primary standard with as little uncertainty as possible. A parallel-plate free-air chamber was designed to measure air kerma of diagnostic X-ray absolutely.
View Article and Find Full Text PDFJ Mass Spectrom
September 2021
Institute of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna, Austria.
Virus-like particles (VLPs) are proteinaceous shells derived from viruses lacking any viral genomic material. Adeno-associated virus (AAV) is a non-enveloped icosahedral virus used as VLP delivery system in gene therapy (GT). Its success as vehicle for GT is due to its selective tropism, high level of transduction, and low immunogenicity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!