Can sonographic findings predict the results of liver aspirates in dogs with suspected liver disease?

Vet Radiol Ultrasound

Department of Veterinary Biomedical Sciences, Faculté de Médecine Vetérinaire, Université de Montréal, Saint-Hyacinthe, QC, Canada.

Published: October 2009

While abdominal ultrasound and ultrasound-guided fine-needle aspiration cytology are often combined to help determine the type of liver disease in dogs, little is known about the relationship that may exist between the results of these tests. We hypothesized that specific sonographic findings, or combinations of findings, may predict results of liver ultrasound-guided fine-needle aspiration cytology. Hepatic and extrahepatic sonographic findings were recorded prospectively using a standardized form in 70 dogs with clinically suspected liver disease and in which liver ultrasound-guided fine-needle aspiration cytology was performed. The predictive value of sonographic findings in regard to the category of cytology results was assessed with stepwise logistic regression analysis. Sonographic detection of a hepatic mass (> or = 3cm; risk ratio [RR] 3.83, 95% Wald confidence intervals [95% CI] 2.42-3.93, P = 0.0036), ascites (RR 3.82, 95% CI 1.94-4.28, P = 0.0044), abnormal hepatic lymph node(s) (RR 3.01, 95% CI 1.22-4.88, P= 0.0262), and abnormal spleen (RR 3.26, 95% CI 1.20-3.85, P = 0.0274) were the most predictive of liver neoplasia on cytology. Conversely, sonographic detection of hepatic nodules (< 3cm; RR 1.97, 95% CI 0.95-2.96, P = 0.0666) was most predictive of vacuolar hepatopathy on cytology. In dogs with suspected liver disease, several sonographic findings, alone or combined, are thus predictive of liver ultrasound-guided fine-needle aspiration cytology results. In the light of the fact that ultrasound-guided fine-needle aspiration cytology of the liver has limitations, these predictabilities could influence the selection of diagnostic tests to reach a reliable diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1740-8261.2009.01572.xDOI Listing

Publication Analysis

Top Keywords

sonographic findings
20
ultrasound-guided fine-needle
20
fine-needle aspiration
20
aspiration cytology
20
suspected liver
12
liver disease
12
liver ultrasound-guided
12
liver
10
findings predict
8
predict liver
8

Similar Publications

Prenatal sonographic diagnosis of congenital heart disease (CHD) can lead to improved morbidity and mortality. However, the diagnostic accuracy of ultrasound, the sole prenatal screening tool, remains limited. Failed prenatal or early newborn detection of cyanotic CHD (CCHD) can have disastrous consequences.

View Article and Find Full Text PDF

Introduction: To correlate the direct and indirect morphological uterus sonographic assessment (MUSA) features of adenomyosis with clinical symptoms severity.

Material And Methods: This observational prospective study was conducted at a tertiary care institute from April 2023 to March 2024, involving 254 women aged 18 to 45 years with a regular menstrual cycle and ultrasound-confirmed diagnosis of adenomyosis. Detailed clinicodemographic data were collected, including symptoms such as painful menses, heavy menstrual bleeding (HMB), chronic pelvic pain (CPP), and bowel/bladder symptoms.

View Article and Find Full Text PDF

Objective: To assess whether premenopausal women diagnosed with deep or ovarian endometriosis on transvaginal sonography (TVS) were more likely to suffer from dyspareunia and pelvic pain symptoms, and have a lower quality of life, compared to women without sonographically diagnosed deep or ovarian endometriosis.

Methods: This was a prospective, cross-sectional study carried out between February 2019 and October 2020 at the general gynecology clinic at University College London Hospital, London, UK. All premenopausal women aged 18-50 years, who were examined consecutively by a single experienced examiner and underwent a detailed TVS scan, were eligible for inclusion.

View Article and Find Full Text PDF

We report a case of small bowel perforation from ileo-ileal intussusception with necrotising enterocolitis (NEC) after indomethacin exposure mimicking spontaneous intestinal perforation in an extremely preterm neonate. Indomethacin exposure can cause mesenteric hypoperfusion, resulting in an ischaemic lead point for intussusception and NEC. We advocate that intussusception should be considered as one of the differentials for neonates with recurrent feeding intolerance postindomethacin exposure.

View Article and Find Full Text PDF

Preterm prelabor rupture of membranes (PPROM) diagnosis is made through visualization of amniotic fluid (pooling), nitrizine testing, sonographic low amniotic fluid, and microscopic detection of amniotic fluid arborization (ferning). Data exits on the specificity and sensitivity of ferning detection but has not focused on the second trimester. Our objective is to evaluate the presence of ferning in transvaginally collected amniotic fluid in pregnancies with known second trimester PPROM to determine if there is a difference in ferning based on gestational age and sample drying time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!