Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To characterize the effect of diffusion time on short-range hyperpolarized (3)He magnetic resonance imaging (MRI) diffusion measurements across a wide range of emphysema severity.
Materials And Methods: (3)He diffusion MRI was performed on 19 lungs or lobes resected from 18 subjects with varying degrees of emphysema using three diffusion times (1.6 msec, 5 msec, and 10 msec) at constant b value. Emphysema severity was quantified as the mean apparent diffusion coefficient (ADC) and as the percentage of pixels with ADC higher than multiple thresholds from 0.30-0.55 cm(2)/sec (ADC index). Quantitative histology (mean linear intercept) was obtained in 10 of the lung specimens from 10 of the subjects.
Results: The mean ADCs with diffusion times of 1.6, 5.0, and 10.0 msec were 0.46, 0.40, and 0.37 cm(2)/sec, respectively (P < 0.0001, analysis of variance [ANOVA]). There was no relationship between the ADC magnitude and the effect of diffusion time on ADC values. The mean linear intercept correlated with ADC (r = 0.91-0.94, P < 0.001) and ADC index (r = 0.78-0.92, P < 0.01) at all diffusion times.
Conclusion: Decreases in ADC with longer diffusion time were unrelated to emphysema severity. The strong correlations between the ADC at all diffusion times tested and quantitative histology demonstrate that ADC is a robust measure of emphysema.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2844435 | PMC |
http://dx.doi.org/10.1002/jmri.21912 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!