Purpose: To carry out a pilot study comparing the size of various types of metallic intraocular foreign bodies as imaged on computed tomographic (CT) scan to their actual size, and to determine the features of different types of metals on CT scan.

Methods: Metallic foreign bodies of predetermined standardized sizes were prepared from iron, silver, copper, aluminium, and lead. The metallic pieces/shards were each inserted into the vitreous of a cow's eye and helical CT scan (MX twin, Picker) was performed to image the intraocular foreign bodies, using soft tissue and bone window settings. Slice section thickness was 1.3 mm, with intervals of 0.6 mm. Milliampere per second was 265 and pitch 0.7.

Results: The size of all types of metals as measured on CT was larger than the actual size. Iron was enlarged by a factor of 2.29, silver 1.77, copper 1.26, and aluminum 1.17. All metals had features including central core, ring density, and artifacts which varied for each type of metal, giving each one a characteristic appearance

Conclusions: Helical CT scan could be useful in estimating the type and size of an intraocular metal foreign body made from iron, silver, copper, aluminium, or lead.

Download full-text PDF

Source
http://dx.doi.org/10.1177/112067210901900528DOI Listing

Publication Analysis

Top Keywords

foreign bodies
16
intraocular foreign
12
helical scan
12
size types
8
actual size
8
types metals
8
iron silver
8
silver copper
8
copper aluminium
8
aluminium lead
8

Similar Publications

"INSERT-COIN": A PROSPECTIVE STUDY OF COIN INGESTION IN CHILDREN OF SOUTHERN ITALY.

Am J Gastroenterol

December 2024

Pediatric Clinic, Department of Surgical and Biomedical Sciences, University of Perugia, 06123 Perugia, Italy.

Background And Aims: Coins are the most commonly ingested foreign bodies. When they get stuck in the distal esophagus there is no general agreement about the timing of their removal, since some of them may spontaneously migrate into the stomach, no longer requiring removal. We aimed at evaluating the gastric spontaneous passage of esophageal-retained coins, as well as complications.

View Article and Find Full Text PDF

Accidental ingestion of foreign bodies frequently necessitates emergency department visits, with many cases requiring surgical consultation. Although most ingested items pass through the gastrointestinal tract uneventfully, orthodontic components, such as wires, present a specific risk due to their shape and material properties. This report describes a rare case of a 13-year-old male adolescent whose initial presentation suggested ingestion of a chicken bone.

View Article and Find Full Text PDF

Intracardiac migration of inferior vena cava (IVC) filter or stent is a rare but potentially fatal complication of endovascular venous device placement. There is no consensus whether migrated stents should be surgically removed by open cardiac surgery or retrieved by the percutaneous endovascular route and whether an intervention should be performed immediately or expectantly. Herein, we report a 39-year-old female who received emergent left lobe living donor liver transplantation (LDLT) owing to posthepatectomy liver failure.

View Article and Find Full Text PDF

A rare case of intrathoracic Gauzoma.

J Cardiothorac Surg

January 2025

Department of Thoracic Surgery, Kobe City Medical Center General Hospital, 2-1-1 Minatojima-Minamimachi, Chuo-ku, Kobe, 650-0047, Japan.

Background: Gauzoma is a foreign body reactive granuloma which is an extremely rare complication of thoracic surgery. We describe a case of a Gauzoma in which the gauzes were removed by mini-thoracotomy as a less invasive procedure, discovered incidentally after 35 years of follow-up.

Case Presentation: A 51-year-old man was referred to our department for hyperhidrosis treatment, and imaging studies and biopsy confirmed the diagnosis of Gauzoma.

View Article and Find Full Text PDF

Background And Purpose:  This study updates 2 parallel systematic reviews and meta-analyses from 2012, which established the 1-year radiostereometric (RSA) migration thresholds for tibial components of total knee replacements (TKR) based on the risk of late revision for aseptic loosening from survival studies. The primary aim of this study was to determine the (mis)categorization rate of the 2012 thresholds using the updated review as a validation dataset. Secondary aims were evaluation of 6-month migration, mean continuous (1- to 2-year) migration, and fixation-specific thresholds for tibial component migration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!