Purpose: Microbial contamination of contact lenses is associated with corneal infection and inflammation. This study determined the microbiological, clinical, and demographic factors that are associated with bacterial contamination of a silicone hydrogel contact lens when worn for continuous wear (CW).

Methods: Two hundred five healthy subjects were enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens Study and were fitted with lotrafilcon A lenses for monthly CW and followed for 1 year. Lenses were aseptically removed after 1 week and 4 months of wear and cultured using an agar sandwich technique. Lids and conjunctiva were routinely cultured at baseline and after 1 week and 4 months of CW. Lenses and ocular sites were considered to have substantial microbial bioburden when they harbored pathogenic organisms or high levels of commensal organisms. Univariate and multivariate logistic regression analyses were conducted to examine whether substantial conjunctival or lid bioburden, subject demographics, lens-wearing history, symptoms, and biomicroscopic signs were associated with lens bioburden.

Results: About one third (32.4%) of subjects had substantial bacterial bioburden in either eye across multiple visits. Over half (53.2%) and about one tenth (11.7%) of subjects had substantial lid and conjunctival bioburden, respectively, and 11.2% discontinued because of discomfort. The adjusted odds ratios (and 95% confidence intervals) for presence of substantial lens bioburden were 2.49 (1.17-5.30), 4.24 (1.45-12.40), and 4.11 (1.17-14.46) for substantial lid bioburden, substantial conjunctival bioburden, and lens discomfort, respectively.

Conclusions: Bacterial contamination of silicone hydrogel contact lenses is common during CW. Substantial lens bioburden is associated with discomfort precluding successful CW. The presence of substantial lid and conjunctival bioburden is associated with a 2.5-fold and more than fourfold greater risk of substantial lens bioburden and is likely the major route of contamination.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2783769PMC
http://dx.doi.org/10.1097/OPX.0b013e3181bbca18DOI Listing

Publication Analysis

Top Keywords

contact lens
12
bacterial contamination
12
silicone hydrogel
12
hydrogel contact
12
substantial lid
12
conjunctival bioburden
12
substantial lens
12
lens bioburden
12
substantial
10
bioburden
10

Similar Publications

Purpose: To characterize the ocular surface microbiota in regular contact lens wearers with dry eyes and assess the effectiveness of reducing bacterial load using a liposomal ozonated oil solution.

Methods: This prospective, longitudinal, controlled study randomized subjects into two groups. Group A (45 subjects) received hydroxypropylmethylcellulose (HPMC, Artific®), while Group B (41 subjects) received ozonated sunflower seed oil with soybean phospholipids (OSSO, Ozonest®).

View Article and Find Full Text PDF

Purpose: The research investigates the efficacy of hydroxypropyl methylcellulose (HPMC) treatment in facilitating the development of compact water droplets on the rear surface of synthetic lenses with capsule imperfections during the process of fluid-air exchange.

Method: This study examined four patients with intraocular lens (IOL) implants and posterior capsule defects who experienced the formation of dense water droplets on the posterior surface following fluid-air exchange. When this occurrence obstructs fundus visualization during surgery, it is recommended to suspend the surgical procedure.

View Article and Find Full Text PDF

Artificial Doctors: Performance of Chatbots as a Tool for Patient Education on Keratoconus.

Eye Contact Lens

December 2024

Department of Ophthalmology (Z.O.O.), Gaziantep State Hospital, Gaziantep, Turkey; Department of Ophthalmology (L.D.), Niğde Ömer Halisdemir University, Niğde, Turkey; and Department of Ophthalmology (I.E.Y.), Gaziantep Dr. Ersin Arslan Training and Research Hospital, Gaziantep, Turkey.

Purpose: We aimed to compare the answers given by ChatGPT, Bard, and Copilot and that obtained from the American Academy of Ophthalmology (AAO) website to patient-written questions related to keratoconus in terms of accuracy, understandability, actionability, and readability to find out whether chatbots can be used in patient education.

Methods: Twenty patient-written questions obtained from the AAO website related to keratoconus were asked to ChatGPT, Bard, and Copilot. Two ophthalmologists independently assessed the answers obtained from chatbots and the AAO website in terms of accuracy, understandability, and actionability according to the Structure of Observed Learning Outcome taxonomy, Patient Education Materials Assessment Tool-Understandability, and Patient Education Materials Assessment Tool-Actionability tests, respectively.

View Article and Find Full Text PDF

Comparative Analysis of Cosmetic and Functional Outcomes in Corneal Tattooing (Keratopigmentation) versus Ocular Prosthesis.

Eye Contact Lens

December 2024

Department of Ophthalmology (E.D., Z.B.S., E.E.E.O., H.O.), Istanbul Medeniyet University Goztepe Prof. Dr. Suleyman Yalçin City Hospital, Istanbul, Turkey; Goztepe Prof. Dr. Suleyman Yalçin City Hospital (O.F.Y.), Department of Ophthalmology, Istanbul, Turkey; and Haydarpasa Numune Education and Research Hospital (M.S.M.), University of Health Sciences, Sadik Eratik Eye Institute, Istanbul, Turkey.

Objectives: This study compares the cosmetic and functional outcomes of corneal tattooing/keratopigmentation and ocular prostheses in rehabilitating disfigured eyes, focusing on esthetic appearance and emotional well-being.

Methods: Ninety-two patients were included: 48 received corneal tattooing, and 44 were fitted with ocular prostheses. Anophthalmic surgery was indicated for trauma, painful blind eye, endophthalmitis, tumor, and corneal ulcer, while corneal tattooing was performed for trauma, corneal ulcer, and endophthalmitis.

View Article and Find Full Text PDF

The design of the prosthetic replacement of the ocular surface ecosystem (PROSE) device allows it to serve as a novel drug delivery system. In this article, we describe the off-label administration of amphotericin B and cenegermin by instillation in the PROSE device reservoir for the treatment of Candida keratitis in the setting of a persistent epithelial defect.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!